Schneider Electric EJB34070 Miniature Circuit Breaker 480Y/277V 70A
Schneider Electric
$2,562.00
E Frame thermal magentic circuit breakers are for use in NF panelboards. These circuit breakers will protect against overload and short circuit conditions. Breakers have a trip indicator. This bolt on circuit breaker has a maximum voltage rating of 480Y/277 VAC. This 3 pole 70 A breaker is rated for HACR applications. Breaker has a breaking capacity of 65 kA at 480Y/277 VAC. Circuit breaker has other breaking capacity ratings based on operting voltage. The breaking capacity code for this circuit breaker is J. Electrical connections are made using aluminum lugs. The lugs on this circuit breaker will accept 14 AWG to 2/0 AWG copper and 12 AWG to 2/0 AWG aluminum wire. Three spaces are used by this circuit breaker. Circuit breaker is 5.66 inches tall, is 2.94 inches wide and 4.05 inches deep. E frame circuit breakers are UL Listed and CSA certified.
- Number Of Poles:
- 3
- Ambient Air Temperature For Operation:
- 40 °C
- Electrical Connection:
- lugs aluminium
- Product Destination:
- NF panelboard
- Product Or Component Type:
- miniature circuit-breaker
- Trip Unit Technology:
- thermal-magnetic
- Breaking Capacity:
- 65 kA 277 V AC || 100 kA 240 V AC || 65 kA 480Y/277 V AC || 100 kA 120 V AC || 100 kA 120/240 V AC
- Net Weight:
- 4 lb(US)
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Rohs Exemption Information:
- Yes
- Product Certifications:
- cULus
- Depth:
- 4.05 in
- Module Type:
- E-Frame
- Circuit Breaker Application:
- HACR rated
- Mercury Free:
- Yes
- Line Rated Current:
- 70 A
- Tightening Torque:
- 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Range Of Product:
- 125 A Frame EDB-EGB-EJB
- Trip Unit Rating:
- 1800-1800 A
- Mounting Mode:
- bolt-on
- Awg Gauge:
- AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Device Short Name:
- EJB
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Holding Current:
- 630 A
- Breaking Capacity Code:
- J
- Local Signalling:
- trip indicator
- Protection Type:
- overload || short-circuit
- [Ue] Rated Operational Voltage:
- 480Y/277 V AC
- Width:
- 2.94 in
- Height:
- 5.66 in
- Number Of Spaces:
- 3
- Number Of Spaces Required:
- 3
- Brochure:
- View
- Datasheet:
- View