Schneider Electric GV2RT10 Gv2 Motor Cb High Inrush 4-6.3A Toggle

(No reviews yet) Write a Review
SKU:
GV2RT10
UPC:
3.38911E+12
Condition:
New
Thermal Protection Adjustment Range:
4-6.3 A IEC 60947-4-1
Device Short Name:
GV2RT
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Suitability For Isolation:
yes IEC 60947-1 § 7-1-6
Warranty:
18 months
Mechanical Robustness:
shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
Trip Unit Technology:
thermal-magnetic
Depth:
78.5 mm
Motor Power Kw:
1.1-1.1 kW 220/230 V AC 50/60 Hz motor protection high peak current || 2.2-2.2 kW 400/415 V AC 50/60 Hz motor protection high peak current || 2.2-2.2 kW 440 V AC 50/60 Hz motor protection high peak current || 3-3 kW 440 V AC 50/60 Hz motor protection
Climatic Withstand:
IACS E10
Operating Altitude:
6561.68 ft (2000 m)
Line Rated Current:
6.3 A
Mercury Free:
Yes
Product Or Component Type:
motor circuit breaker
Height:
89 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Product Certifications:
CCC || UL || CSA || EAC || LROS (Lloyds register of shipping) || BV || UKCA
Network Frequency:
50/60 Hz IEC 60947-4-1
Device Application:
motor protection || transformer
Sustainable Offer Status:
Green Premium product
Mechanical Durability:
100000 cycles
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
Network Type:
AC
Rated Duty:
continuous IEC 60947-4-1
Rohs Exemption Information:
Yes
Ik Degree Of Protection:
IK04
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage:
-40-80 °C
Range:
TeSys Deca
Magnetic Tripping Current:
138-138 A
Breaking Capacity:
100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Product Name:
TeSys GV2 || TeSys Deca
Circularity Profile:
ENVEOLI121004
[Ith] Conventional Free Air Thermal Current:
6.3 A IEC 60947-4-1
Poles Description:
3P
Ambient Air Temperature For Operation:
-20-60 °C
Fire Resistance:
960 °C IEC 60695-2-11
Control Type:
toggle
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP121004
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Ip Degree Of Protection:
IP20 IEC 60529
Standards:
EN/IEC 60947-2 || EN/IEC 60947-4-1
Eu Rohs Directive:
Compliant with Exemptions
Tightening Torque:
1.7 N.m screw clamp terminal
Power Dissipation Per Pole:
2.5 W
Width:
45 mm
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Datasheet:
View
  • Schneider Electric GV2RT10 Gv2 Motor Cb High Inrush 4-6.3A Toggle
  • Schneider Electric GV2RT10 Gv2 Motor Cb High Inrush 4-6.3A Toggle
$180.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for high starting current peak motor applications 2.2kW@400V. It provides a thermal-magnetic protection with a thermal setting range 4-6.3A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose