Schneider Electric GV4AE11 Auxiliary Contact Of Or Sd Gv4 & Bv4
Schneider Electric
$50.00
TeSys GV4 auxiliary contact block, for motor circuit breakers GV4. 1C/O contact, it performs Open/Close OF function or Trip alarm SD function, depending of its location in the circuit breaker. Rated for operation up to 5A/690V AC and 5A/250V DC. To be plugged inside the circuit breaker, in the right-hand cavity for OF function, in the left-hand cavity for SD function, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
- Connections - Terminals:
- spring terminals 1 0.5-1.5 mm² - cable stiffness: flexible without cable end
- Mechanical Durability:
- 40000 cycles
- Device Application:
- signalling
- Rated Power In Va:
- 120 VA AC-12 24 V IEC 60947-5-1 || 240 VA AC-12 48 V IEC 60947-5-1 || 635 VA AC-12 110/127 V IEC 60947-5-1 || 1200 VA AC-12 230/240 V IEC 60947-5-1 || 2200 VA AC-12 380/440 V IEC 60947-5-1 || 3450 VA AC-12 660/690 V IEC 60947-5-1
- Sustainable Offer Status:
- Green Premium product
- Mercury Free:
- Yes
- Mounting Mode:
- internal mounting
- Quantity Per Set:
- set of 1
- [Ui] Rated Insulation Voltage:
- 690 V IEC 60947-1
- Associated Fuse Rating:
- 5 A gG at 690 V conforming to IEC 60947-5-1
- Circularity Profile:
- ENVEOLI1704004EN
- Auxiliary Contact Composition:
- 1 NO/NC
- Reach Free Of Svhc:
- Yes
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- [Ue] Rated Operational Voltage:
- <= 690 V
- Minimum Switching Voltage:
- 17 V
- Rohs Exemption Information:
- Yes
- Device Short Name:
- GV4AE
- Toxic Heavy Metal Free:
- Yes
- Eu Rohs Directive:
- Compliant
- Range:
- TeSys
- [Ie] Rated Operational Current:
- 5 A <= 690 V AC-12 IEC 60947-5-1 || 0.3 A 250 V DC-12 IEC 60947-5-1 || 2.5 A <= 24 V DC-12 IEC 60947-5-1 || 1.2 A 48 V DC-12 IEC 60947-5-1 || 0.35 A 110/127 V DC-12 IEC 60947-5-1 || 0.05 A 250 V DC-12 IEC 60947-5-1 || 1 A <= 24 V DC-12 IEC 60947-5-1
- Rated Power In W:
- DC-12 120 W 24 V IEC 60947-5-1 || DC-12 120 W 48 V IEC 60947-5-1 || DC-12 66 W 110 V IEC 60947-5-1 || DC-12 75 W 250 V IEC 60947-5-1
- Minimum Switching Current:
- 2 mA
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Ith] Conventional Free Air Thermal Current:
- 5 A IEC 60947-5-1 || 5 A CSA C22.2 No 14 || 5 A UL 508
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Range Compatibility:
- TeSys TeSys GV4 || TeSys TeSys BV4
- Environmental Disclosure:
- ENVPEP1704004EN
- Wire Stripping Length:
- 8 mm
- Product Or Component Type:
- auxiliary contact
- Catalog:
- View
- Datasheet:
- View