Schneider Electric

Schneider Electric GV4P115B Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4P115B
MPN:
GV4P115B
Condition:
New
Product Or Component Type:
motor circuit breaker
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Warranty:
18 months
Phase Failure Sensitivity:
yes IEC 60947-4-1
Pvc Free:
Yes
Range Of Product:
TeSys GV4
Rated Duty:
continuous IEC 60947-4-1
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Circularity Profile:
ENVEOLI1704004EN
Line Rated Current:
115 A
Operating Altitude:
5000 m
Breaking Capacity:
50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 35 kA 208Y/120 V AC 50/60 Hz UL 60947 || 35 kA 240 V AC 50/60 Hz U
Trip Unit Technology:
thermal-magnetic || electronic
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Magnetic Tripping Current:
1955-1955 A
Rohs Exemption Information:
Yes
Product Name:
TeSys GV4 || TeSys Deca
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Operating Position:
any position
Mechanical Durability:
40000 cycles
Ambient Air Temperature For Storage:
-50-85°C
Maximum Operating Rate:
25 cyc/h
Country of Origin:
Mexico
Sustainable Offer Status:
Green Premium product
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Climatic Withstand:
IACS E10
Weight:
1.6 kg
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Height:
155 mm
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Device Application:
motor protection
Halogen Content Performance:
Halogen free plastic parts product
Fire Resistance:
960°C IEC 60695-2-11
Ip Degree Of Protection:
IP40 IEC 60529
Device Short Name:
GV4P
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...6
Depth:
165 mm
Suitability For Isolation:
yes IEC 60947-1
Eu Rohs Directive:
Compliant with Exemptions
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Control Type:
rotary handle
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mercury Free:
Yes
Ik Degree Of Protection:
IK07 IEC 62262
$745.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 25kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose