Schneider Electric

Schneider Electric GV4P115B6 Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4P115B6
MPN:
GV4P115B6
Condition:
New
Net Weight:
1.6 kg
Ambient Air Temperature For Storage:
-50-85°C
Country of Origin:
Poland
Trip Unit Technology:
electronic || thermal-magnetic
Phase Failure Sensitivity:
yes IEC 60947-4-1
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Control Type:
rotary handle
Operating Position:
any position
Circularity Profile:
ENVEOLI1704004EN
Climatic Withstand:
IACS E10
Mercury Free:
Yes
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...6
Suitability For Isolation:
yes IEC 60947-1
Environmental Disclosure:
ENVPEP1704004EN
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Eu Rohs Directive:
Compliant with Exemptions
Pvc Free:
Yes
Weight:
1.6 kg
Depth:
165 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Rohs Exemption Information:
Yes
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Warranty:
18 months
Magnetic Tripping Current:
1955-1955 A
Device Short Name:
GV4P
Rated Duty:
continuous IEC 60947-4-1
Ik Degree Of Protection:
IK07 IEC 62262
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Operating Altitude:
5000 m
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Maximum Operating Rate:
25 cyc/h
Product Or Component Type:
motor circuit breaker
Product Name:
TeSys GV4 || TeSys Deca
Connections - Terminals:
lugs-ring terminals
Line Rated Current:
115 A
Breaking Capacity:
50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 35 kA 208Y/120 V AC 50/60 Hz UL 60947 || 35 kA 240 V AC 50/60 Hz U
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ip Degree Of Protection:
IP40 IEC 60529
Halogen Content Performance:
Halogen free plastic parts product
Poles Description:
3P
Device Application:
motor protection
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
$745.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 25kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose