Schneider Electric

Schneider Electric GV4P25N6 Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4P25N6
MPN:
GV4P25N6
Condition:
New
Phase Failure Sensitivity:
yes IEC 60947-4-1
Rohs Exemption Information:
Yes
Ik Degree Of Protection:
IK07 IEC 62262
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Range Of Product:
TeSys GV4
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Product Name:
TeSys GV4 || TeSys Deca
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Range:
TeSys Deca
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
81 mm
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Weight:
1.6 kg
Maximum Operating Rate:
25 cyc/h
Motor Power Kw:
7.5-7.5 kW 660...690 V AC 50/60 Hz || 5.5-5.5 kW 400...415 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz || 9-9 kW 660...690 V AC 50/60 Hz || 11-11 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 400...415 V AC 50/60 Hz || 9-9 kW 400...415 V AC 50/60 Hz ||
Trip Unit Technology:
electronic || thermal-magnetic
Mechanical Durability:
40000 cycles
Line Rated Current:
25 A
Product Or Component Type:
motor circuit breaker
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Operating Position:
any position
Rated Duty:
continuous IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Power Dissipation Per Pole:
4.6 W
Halogen Content Performance:
Halogen free plastic parts product
Environmental Disclosure:
ENVPEP1704004EN
Country of Origin:
Poland
Eu Rohs Directive:
Compliant with Exemptions
Poles Description:
3P
Operating Altitude:
5000 m
Magnetic Tripping Current:
425-425 A
Sustainable Offer Status:
Green Premium product
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Pollution Degree:
3
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 20000 cycles AC-3 440 V In
Connections - Terminals:
lugs-ring terminals
Suitability For Isolation:
yes IEC 60947-1
Ambient Air Temperature For Operation:
-25-70°C
Net Weight:
1.6 kg
Device Short Name:
GV4P
Ambient Air Temperature For Storage:
-50-85°C
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Control Type:
rotary handle
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pvc Free:
Yes
Color:
Gray RAL 7016)
$1,192.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 10-25A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose