Schneider Electric GV4P25N6 Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, lugs terminals
Schneider Electric
$1,192.50
TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 10-25A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
- Phase Failure Sensitivity:
- yes IEC 60947-4-1
- Rohs Exemption Information:
- Yes
- Ik Degree Of Protection:
- IK07 IEC 62262
- Tightening Torque:
- 9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
- Range Of Product:
- TeSys GV4
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Product Name:
- TeSys GV4 || TeSys Deca
- Product Certifications:
- IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
- Range:
- TeSys Deca
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Width:
- 81 mm
- Mercury Free:
- Yes
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Weight:
- 1.6 kg
- Maximum Operating Rate:
- 25 cyc/h
- Motor Power Kw:
- 7.5-7.5 kW 660...690 V AC 50/60 Hz || 5.5-5.5 kW 400...415 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz || 9-9 kW 660...690 V AC 50/60 Hz || 11-11 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 400...415 V AC 50/60 Hz || 9-9 kW 400...415 V AC 50/60 Hz ||
- Trip Unit Technology:
- electronic || thermal-magnetic
- Mechanical Durability:
- 40000 cycles
- Line Rated Current:
- 25 A
- Product Or Component Type:
- motor circuit breaker
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1
- Operating Position:
- any position
- Rated Duty:
- continuous IEC 60947-4-1
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Power Dissipation Per Pole:
- 4.6 W
- Halogen Content Performance:
- Halogen free plastic parts product
- Environmental Disclosure:
- ENVPEP1704004EN
- Country of Origin:
- Poland
- Eu Rohs Directive:
- Compliant with Exemptions
- Poles Description:
- 3P
- Operating Altitude:
- 5000 m
- Magnetic Tripping Current:
- 425-425 A
- Sustainable Offer Status:
- Green Premium product
- Connection Pitch:
- 27 mm without spreaders || 35 mm with spreaders
- [Ui] Rated Insulation Voltage:
- 800 V AC 50/60 Hz IEC 60947-2
- Pollution Degree:
- 3
- Electrical Durability:
- 40000 cycles AC-3 440 V In/2 || 20000 cycles AC-3 440 V In
- Connections - Terminals:
- lugs-ring terminals
- Suitability For Isolation:
- yes IEC 60947-1
- Ambient Air Temperature For Operation:
- -25-70°C
- Net Weight:
- 1.6 kg
- Device Short Name:
- GV4P
- Ambient Air Temperature For Storage:
- -50-85°C
- Breaking Capacity:
- 100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
- Control Type:
- rotary handle
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Pvc Free:
- Yes
- Color:
- Gray RAL 7016)