Schneider Electric

Schneider Electric GV4PB115B Motor circuit breaker, TeSys Deca, 3P, 115A, Icu 25kA, thermal magnetic, multifunction, UL489

(No reviews yet) Write a Review
SKU:
GV4PB115B
MPN:
GV4PB115B
Condition:
New
Circularity Profile:
ENVEOLI1704004EN
Product Name:
TeSys GV4 || TeSys Deca
Operating Position:
any position
Environmental Disclosure:
ENVPEP1704004EN
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
Ik Degree Of Protection:
IK07 IEC 62262
Trip Unit Technology:
thermal-magnetic || electronic
Product Certifications:
IEC || UL || CSA
Device Short Name:
GV4PB
Halogen Content Performance:
Halogen free plastic parts product
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Net Weight:
1.45 kg
Rohs Exemption Information:
Yes
Country of Origin:
Poland
Mechanical Durability:
40000 cycles
Suitability For Isolation:
yes IEC 60947-1
Color:
Gray RAL 7016)
Ambient Air Temperature For Operation:
-25-70°C
Phase Failure Sensitivity:
yes IEC 60947-4-1
Eu Rohs Directive:
Compliant with Exemptions
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
Range Of Product:
TeSys GV4
Device Application:
motor protection
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Power Dissipation Per Pole:
4.6 W
Fire Resistance:
960°C IEC 60695-2-11
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Climatic Withstand:
IACS E10
Range:
TeSys Deca
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Maximum Operating Rate:
25 cyc/h
Product Or Component Type:
motor circuit breaker
Mercury Free:
Yes
Poles Description:
3P
Ip Degree Of Protection:
IP40 IEC 60529
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Storage:
-50-85°C
Line Rated Current:
115 A
Magnetic Tripping Current:
1955-1955 A
Depth:
116 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Weight:
1.45 kg
Breaking Capacity:
35 kA SCCR 240 V AC 60 Hz UL 489 || 18 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 14 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 50 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 20 kA Icu 440 V AC 50/60 Hz IEC 60947-
$466.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 25kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).
View AllClose