Schneider Electric

Schneider Electric GV4PB50S Motbreakgv4Pbul489Th/Mag 50A 100Ka Elink

(No reviews yet) Write a Review
SKU:
GV4PB50S
UPC:
3606489868680
Condition:
New
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Poles Description:
3P
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Environmental Disclosure:
ENVPEP1704004EN
Electrical Durability:
20000 cycles AC-3 440 V In/2 || 10000 cycles AC-3 440 V In
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Device Application:
motor protection
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Color:
Gray RAL 7016)
Breaking Capacity:
100 kA SCCR 240 V AC 60 Hz UL 489 || 65 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 25 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 120 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 609
Mechanical Durability:
40000 cycles
Control Type:
toggle
Power Dissipation Per Pole:
4.6 W
Eu Rohs Directive:
Compliant with Exemptions
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 525 V AC 50/60 Hz IEC 60947-2 || 25 % 660/690 V AC 50/60 Hz IEC 60947-2
Device Short Name:
GV4PB
Halogen Content Performance:
Halogen free plastic parts product
Line Rated Current:
50 A
Phase Failure Sensitivity:
yes IEC 60947-4-1
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
Circularity Profile:
ENVEOLI1704004EN
Magnetic Tripping Current:
850-850 A
Depth:
116 mm
Ambient Air Temperature For Storage:
-50-85 °C
Ik Degree Of Protection:
IK07 IEC 62262
Fire Resistance:
960 °C IEC 60695-2-11
Pollution Degree:
3
Maximum Operating Rate:
25 cyc/h
Rated Duty:
continuous IEC 60947-4-1
Ambient Air Temperature For Operation:
-25-70 °C
Range Of Product:
TeSys GV4
Operating Altitude:
5000 m
Sustainable Offer Status:
Green Premium product
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Operating Position:
any position
Product Certifications:
IEC || UL || CSA
Climatic Withstand:
IACS E10
Height:
171 mm
Mercury Free:
Yes
Warranty:
18 months
Trip Unit Technology:
electronic || thermal-magnetic
Product Name:
TeSys GV4 || TeSys Deca
Range:
TeSys Deca
Net Weight:
1.45 kg
Pvc Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ip Degree Of Protection:
IP40 IEC 60529
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rohs Exemption Information:
Yes
Width:
81 mm
Product Or Component Type:
motor circuit breaker
Suitability For Isolation:
yes IEC 60947-1
Datasheet:
View
$551.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).
View AllClose