Schneider Electric

Schneider Electric GV4PE03N6 Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4PE03N6
MPN:
GV4PE03N6
Condition:
New
Range:
TeSys Deca
Rated Duty:
continuous IEC 60947-4-1
Width:
81 mm
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Operating Altitude:
5000 m
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Ambient Air Temperature For Operation:
-25-70°C
Depth:
116 mm
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Operating Position:
any position
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Rohs Exemption Information:
Yes
Product Name:
TeSys GV4 || TeSys Deca
Mercury Free:
Yes
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Color:
Gray RAL 7016)
Trip Unit Technology:
thermal-magnetic || electronic
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP1704004EN
Maximum Operating Rate:
25 cyc/h
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Motor Power Kw:
0.55-0.55 kW 400...415 V AC 50/60 Hz || 0.75-0.75 kW 400...415 V AC 50/60 Hz || 0.75-0.75 kW 500 V AC 50/60 Hz || 1.1-1.1 kW 500 V AC 50/60 Hz || 1.1-1.1 kW 660...690 V AC 50/60 Hz || 1.5-1.5 kW 660...690 V AC 50/60 Hz || 1.5-1.5 kW 500 V AC 50/60 Hz
Halogen Content Performance:
Halogen free plastic parts product
Ik Degree Of Protection:
IK07 IEC 62262
Phase Failure Sensitivity:
yes IEC 60947-4-1
Suitability For Isolation:
yes IEC 60947-1
Power Dissipation Per Pole:
4.6 W
Mechanical Durability:
40000 cycles
Weight:
1.45 kg
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Product Or Component Type:
motor circuit breaker
Pvc Free:
Yes
Range Of Product:
TeSys GV4
Line Rated Current:
3.5 A
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Device Application:
motor protection
Connections - Terminals:
lugs-ring terminals
Pollution Degree:
3
Poles Description:
3P
Control Type:
toggle
Magnetic Tripping Current:
59-59 A
$1,117.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 1.4-3.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose