Schneider Electric

Schneider Electric GV4PE80S Motor circuit breaker, TeSys GV4, 3P, 80A, Icu 100kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PE80S
MPN:
GV4PE80S
Condition:
New
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Poles Description:
3P
Net Weight:
1.45 kg
Circularity Profile:
ENVEOLI1704004EN
Depth:
116 mm
Environmental Disclosure:
ENVPEP1704004EN
Fire Resistance:
960°C IEC 60695-2-11
Line Rated Current:
80 A
Mechanical Durability:
40000 cycles
Pollution Degree:
3
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Electrical Durability:
14000 cycles AC-3 440 V In/2 || 7000 cycles AC-3 440 V In
Range Of Product:
TeSys GV4
Breaking Capacity:
120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 208Y/120 V AC
Phase Failure Sensitivity:
yes IEC 60947-4-1
Operating Position:
any position
Climatic Withstand:
IACS E10
Ambient Air Temperature For Storage:
-50-85°C
Ik Degree Of Protection:
IK07 IEC 62262
Product Or Component Type:
motor circuit breaker
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Operating Altitude:
5000 m
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Trip Unit Technology:
thermal-magnetic || electronic
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Pvc Free:
Yes
Range:
TeSys Deca
Ambient Air Temperature For Operation:
-25-70°C
Control Type:
toggle
Power Dissipation Per Pole:
4.6 W
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Mercury Free:
Yes
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 30-30 kW 500 V AC 50/60 Hz || 37-37 kW 660...690 V AC 50/60 Hz || 45-45 kW 660...690 V AC 50/60 Hz || 55-55 kW 660...690 V AC 50/60 Hz || 30-30 kW 4
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Sustainable Offer Status:
Green Premium product
Rated Duty:
continuous IEC 60947-4-1
Eu Rohs Directive:
Compliant with Exemptions
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Warranty:
18 months
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Maximum Operating Rate:
25 cyc/h
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Suitability For Isolation:
yes IEC 60947-1
Product Name:
TeSys GV4 || TeSys Deca
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
$945.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 80A/690V, for protection of 3-phase motors 22-37kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 40-80A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose