Schneider Electric

Schneider Electric GV4PEM115N6 Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic multifunction, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4PEM115N6
MPN:
GV4PEM115N6
Condition:
New
Net Weight:
1.45 kg
Range Of Product:
TeSys GV4
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Range:
TeSys Deca
Rated Duty:
continuous IEC 60947-4-1
Operating Position:
any position
Weight:
1.45 kg
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Ip Degree Of Protection:
IP40 IEC 60529
Mechanical Durability:
40000 cycles
Suitability For Isolation:
yes IEC 60947-1
Eu Rohs Directive:
Compliant with Exemptions
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Magnetic Tripping Current:
1955-1955 A
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Rohs Exemption Information:
Yes
Halogen Content Performance:
Halogen free plastic parts product
Device Application:
motor protection
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Storage:
-50-85°C
Ik Degree Of Protection:
IK07 IEC 62262
Control Type:
toggle
Climatic Withstand:
IACS E10
Warranty:
18 months
Device Short Name:
GV4PEM
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Connections - Terminals:
lugs-ring terminals
Ambient Air Temperature For Operation:
-25-70°C
Color:
Gray RAL 7016)
Maximum Operating Rate:
25 cyc/h
Power Dissipation Per Pole:
4.6 W
Width:
81 mm
Country of Origin:
Poland
Fire Resistance:
960°C IEC 60695-2-11
Operating Altitude:
5000 m
Poles Description:
3P
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Product Name:
TeSys GV4 || TeSys Deca
Depth:
116 mm
Phase Failure Sensitivity:
yes IEC 60947-4-1
$1,492.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose