Schneider Electric

Schneider Electric GV4PEM50N Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic multifunction, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PEM50N
MPN:
GV4PEM50N
Condition:
New
Halogen Content Performance:
Halogen free plastic parts product
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Device Short Name:
GV4PEM
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP1704004EN
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Suitability For Isolation:
yes IEC 60947-1
Mechanical Durability:
40000 cycles
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Country of Origin:
Poland
Ambient Air Temperature For Storage:
-50-85°C
Mercury Free:
Yes
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Magnetic Tripping Current:
850-850 A
Depth:
116 mm
Phase Failure Sensitivity:
yes IEC 60947-4-1
Trip Unit Technology:
electronic || thermal-magnetic
Weight:
1.45 kg
Rated Duty:
continuous IEC 60947-4-1
Pvc Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ik Degree Of Protection:
IK07 IEC 62262
Control Type:
toggle
Fire Resistance:
960°C IEC 60695-2-11
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Range:
TeSys Deca
Electrical Durability:
20000 cycles AC-3 440 V In/2 || 10000 cycles AC-3 440 V In
Color:
Gray RAL 7016)
Pollution Degree:
3
Maximum Operating Rate:
25 cyc/h
Ambient Air Temperature For Operation:
-25-70°C
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Operating Altitude:
5000 m
Sustainable Offer Status:
Green Premium product
Power Dissipation Per Pole:
4.6 W
Device Application:
motor protection
Ip Degree Of Protection:
IP40 IEC 60529
Climatic Withstand:
IACS E10
Net Weight:
1.45 kg
Eu Rohs Directive:
Compliant with Exemptions
Line Rated Current:
50 A
Motor Power Kw:
11-11 kW 400...415 V AC 50/60 Hz || 15-15 kW 500 V AC 50/60 Hz || 18.5-18.5 kW 660...690 V AC 50/60 Hz || 15-15 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 400...415 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 500 V AC 50/60 Hz |
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Rohs Exemption Information:
Yes
Width:
81 mm
Warranty:
18 months
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
$845.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose