Schneider Electric GVAU025 Tesys Undervolt Trip 24V Rhs Mt

(No reviews yet) Write a Review
SKU:
GVAU025
UPC:
3389110344158
Condition:
New
Reach Free Of Svhc:
Yes
On-Load Factor:
1
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Product Or Component Type:
undervoltage release
Range:
TeSys || TeSys Deca
[Ui] Rated Insulation Voltage:
690 V AC IEC 60947-1 || 600 V AC UL 60947-4-1 || 600 V AC CSA C22.2 No 60947-4-1
Operating Time:
10...15 ms IEC 60947-1
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Height:
89 mm
Color:
dark grey
Connections - Terminals:
screw clamp terminals 1 1-2.5 mm²solid || screw clamp terminals 2 1-2.5 mm²solid || screw clamp terminals 1 0.75-2.5 mm²flexible without cable end || screw clamp terminals 2 0.75-2.5 mm²flexible without cable end || screw clamp terminals 1 0.75-1.5 m
Inrush Power In Va:
12-12 VA AC
Width:
18 mm
Warranty:
18 months
Rohs Exemption Information:
Yes
Device Short Name:
GVAU
Control Circuit Voltage Limits:
0.85...1.1 Un
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Threshold Tripping Voltage:
0.7...0.35 Un
Inrush Power In W:
8 W
Depth:
66 mm
Toxic Heavy Metal Free:
Yes
Range Compatibility:
TeSys GV2ME || TeSys GV2LE || TeSys GV2L || TeSys GV2P || TeSys GV3L || TeSys GV3P || TeSys Deca
Mercury Free:
Yes
Quantity Per Set:
set of 10
[Uc] Control Circuit Voltage:
24 V AC 50 Hz
Hold-In Power Consumption In W:
1.1-1.1 W
Mechanical Durability:
10000 cycles with GV3P and GV3L || 30000 cycles with GV2ME and GV2P
Hold-In Power Consumption In Va:
3.5-3.5 VA AC
Tightening Torque:
< 1.4 N.m screw clamp terminals
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Net Weight:
0.105 kg
Eu Rohs Directive:
Compliant
$81.00

Description

TeSys GV electrical trip, MN undervoltage release, 24V AC 50Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage is applied in the range 0.85-1.1 Uc. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose