Schneider Electric

Schneider Electric GVAU415 Tesys Undervolt Trip 415V Rhs Mt

(No reviews yet) Write a Review
SKU:
GVAU415
UPC:
3389110346046
Condition:
New
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Color:
dark grey
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Hold-In Power Consumption In W:
1.1-1.1 W
Device Short Name:
GVAU
On-Load Factor:
1
Mechanical Durability:
10000 cycles with GV3P and GV3L || 30000 cycles with GV2ME and GV2P
Product Or Component Type:
undervoltage release
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Connections - Terminals:
screw clamp terminals 1 1-2.5 mm²solid || screw clamp terminals 2 1-2.5 mm²solid || screw clamp terminals 1 0.75-2.5 mm²flexible without cable end || screw clamp terminals 2 0.75-2.5 mm²flexible without cable end || screw clamp terminals 1 0.75-1
Warranty:
18 months
Control Circuit Voltage Limits:
0.85...1.1 Un
Hold-In Power Consumption In Va:
3.5-3.5 VA AC
Net Weight:
0.105 kg
Depth:
66 mm
Inrush Power In W:
8 W
Range:
TeSys || TeSys Deca
Quantity Per Set:
set of 10
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Range Compatibility:
TeSys GV2ME || TeSys GV2LE || TeSys GV2L || TeSys GV2P || TeSys GV3L || TeSys GV3P || TeSys Deca
Tightening Torque:
< 1.4 N.m screw clamp terminals
Reach Free Of Svhc:
Yes
Inrush Power In Va:
12-12 VA AC
Threshold Tripping Voltage:
0.7...0.35 Un
Width:
18 mm
Rohs Exemption Information:
Yes
[Ui] Rated Insulation Voltage:
690 V AC IEC 60947-1 || 600 V AC UL 60947-4-1 || 600 V AC CSA C22.2 No 60947-4-1
Toxic Heavy Metal Free:
Yes
Height:
89 mm
[Uc] Control Circuit Voltage:
415...440 V AC 50 Hz || 480 V AC 60 Hz
Operating Time:
10...15 ms IEC 60947-1
Datasheet:
View
$81.00

Description

TeSys GV electrical trip, MN undervoltage release, 415-440V AC 50Hz / 480V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage is applied in the range 0.85-1.1 Uc. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).