[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Terminal Identifier:
AL150HD
Breaking Capacity Code:
D
Eu Rohs Directive:
Compliant
Poles Description:
2P
Rohs Exemption Information:
Yes
Range:
PowerPact
Pvc Free:
Yes
Mounting Mode:
unit mount lug)
Pollution Degree:
3 IEC 60947-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Utilisation Category:
category A
Quantity Per Set:
1
Magnetic Hold Current:
350 A
Communication Interface:
Modbus || Ethernet
Electrical Connection:
lugs, line || lugs, load
Warranty:
18 months
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Ip Degree Of Protection:
front cover IP40 IEC 60529
Product Certifications:
UL || CSA || NOM
Color:
Black
Line Rated Current:
15-15 A
Sustainable Offer Status:
Green Premium product
Net Weight:
2.2 kg
Control Type:
toggle
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mounting Support:
lug
Wire Stripping Length:
16 mm
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Ambient Air Temperature For Storage:
-50-85 °C
Trip Unit Technology:
thermal-magnetic
Depth:
86 mm
Magnetic Tripping Current:
750-750 A
Suitability For Isolation:
yes IEC 60947-2
Protected Poles Description:
2t
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Environmental Disclosure:
ENVPEP1311006EN
Local Signalling:
switched off (OFF) 1 trip indicator green)
Circularity Profile:
ENVEOLI1311006EN
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Height:
163 mm
Ambient Air Temperature For Operation:
-2-70 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Circuit Breaker Application:
HACR rated
Quality Labels:
CE
Product Name:
PowerPact H
Device Application:
distribution
Network Frequency:
50/60 Hz
Width:
104 mm
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mercury Free:
Yes
Continuous Current Rating:
1
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Or Component Type:
circuit breaker
$2,349.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 15A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.