Schneider Electric HDL36060 Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HDL36060
UPC:
785901577959
Condition:
New
Width:
104 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Product Or Component Type:
circuit breaker
Product Certifications:
UL || CSA || NOM
Communication Interface:
Modbus || Ethernet
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Device Application:
distribution
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Protected Poles Description:
3t
Eu Rohs Directive:
Compliant with Exemptions
Circularity Profile:
ENVEOLI2206027EN
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Depth:
86 mm
Mercury Free:
Yes
Electrical Connection:
lugs, line || lugs, load
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Continuous Current Rating:
0.8
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Terminal Identifier:
AL150HD
Line Rated Current:
60-60 A
Mounting Support:
lug
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Local Signalling:
switched off (OFF) 1 trip indicator green)
Network Frequency:
50/60 Hz
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Sustainable Offer Status:
Green Premium product
Mounting Mode:
unit mount lug)
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Ip Degree Of Protection:
front cover IP40 IEC 60529
Utilisation Category:
category A
Quantity Per Set:
1
Suitability For Isolation:
yes IEC 60947-2
Control Type:
toggle
Poles Description:
3P
Range:
PowerPact
Circuit Breaker Application:
HACR rated
Warranty:
18 months
Environmental Disclosure:
ENVPEP2206027EN
Trip Unit Technology:
thermal-magnetic
Wire Stripping Length:
16 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Ambient Air Temperature For Storage:
-50-85 °C
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Ambient Air Temperature For Operation:
-2-70 °C
Magnetic Hold Current:
800 A
Quality Labels:
CE
Color:
Black
Magnetic Tripping Current:
1450-1450 A
Breaking Capacity Code:
D
Net Weight:
2.2 kg
Pollution Degree:
3 IEC 60947-1
Product Name:
PowerPact H
Height:
163 mm
Pvc Free:
Yes
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HDL36060 Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HDL36060 Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HDL36060 Molded Case Circuit Breaker 600V 60A
$1,088.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose