Schneider Electric HGA261001 Molded Case Circuit Breaker 600V 100A

(No reviews yet) Write a Review
SKU:
HGA261001
UPC:
785901651529
Condition:
New
Product Or Component Type:
circuit breaker
Suitability For Isolation:
yes IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Support:
bracket
Communication Interface:
Modbus || Ethernet
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Network Frequency:
50/60 Hz
Terminal Identifier:
AL150HD
Mounting Mode:
I-Line bracket)
Product Name:
PowerPact H
Local Signalling:
switched off (OFF) 1 trip indicator green)
Circularity Profile:
ENVEOLI2206027EN
Range:
PowerPact
Color:
Black
Pollution Degree:
3 IEC 60947-1
Device Application:
distribution
Product Certifications:
UL || CSA || NOM
Pvc Free:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Wire Stripping Length:
16 mm
Magnetic Hold Current:
900 A
Sustainable Offer Status:
Green Premium product
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Phase Connection:
AB
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Line Rated Current:
100-100 A
Mercury Free:
Yes
Breaking Capacity Code:
G
Utilisation Category:
category A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Quality Labels:
CE
Poles Description:
2P
Eu Rohs Directive:
Compliant with Exemptions
Electrical Connection:
I-Line connection, line || lugs, load
Ambient Air Temperature For Operation:
-2-70 °C
Ip Degree Of Protection:
front cover IP40 IEC 60529
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Continuous Current Rating:
0.8
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Rohs Exemption Information:
Yes
Width:
104 mm
Control Type:
toggle
Warranty:
18 months
Ambient Air Temperature For Storage:
-50-85 °C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Circuit Breaker Application:
HACR rated
Mounting Height:
3 in
Quantity Per Set:
1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Height:
163 mm
Trip Unit Technology:
thermal-magnetic
Magnetic Tripping Current:
1700-1700 A
Net Weight:
2.2 kg
Depth:
86 mm
Environmental Disclosure:
ENVPEP2206027EN
Protected Poles Description:
2t
$1,559.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose