
Schneider Electric HGA261504 Molded Case Circuit Breaker 600V 150A
Schneider Electric
$4,818.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 150A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Product Or Component Type:
- circuit breaker
- Eu Rohs Directive:
- Compliant
- Control Type:
- toggle
- Electrical Connection:
- I-Line connection, line || lugs, load
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Poles Description:
- 2P
- Suitability For Isolation:
- yes IEC 60947-2
- Breaking Capacity Code:
- G
- Line Rated Current:
- 150-150 A
- Ambient Air Temperature For Operation:
- -2-70 °C
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Communication Interface:
- Modbus || Ethernet
- Ambient Air Temperature For Storage:
- -50-85 °C
- Depth:
- 86 mm
- Phase Connection:
- BC
- Mounting Support:
- bracket
- Sustainable Offer Status:
- Green Premium product
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Quantity Per Set:
- 1
- Terminal Identifier:
- AL150HD
- Pvc Free:
- Yes
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Quality Labels:
- CE
- Pollution Degree:
- 3 IEC 60947-1
- Height:
- 163 mm
- Continuous Current Rating:
- 0.8
- Environmental Disclosure:
- ENVPEP1311006EN
- Protected Poles Description:
- 2t
- Range:
- PowerPact
- Utilisation Category:
- category A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Circuit Breaker Application:
- HACR rated
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Product Name:
- PowerPact H
- Trip Unit Technology:
- thermal-magnetic
- Color:
- Black
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Magnetic Hold Current:
- 900 A
- Circularity Profile:
- ENVEOLI1311006EN
- Net Weight:
- 2.2 kg
- Mercury Free:
- Yes
- Wire Stripping Length:
- 16 mm
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Device Application:
- distribution
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Magnetic Tripping Current:
- 1700-1700 A
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Rohs Exemption Information:
- Yes
- Network Frequency:
- 50/60 Hz
- Mounting Height:
- 3 in
- Mounting Mode:
- I-Line bracket)
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Product Certifications:
- UL || CSA || NOM
- Width:
- 104 mm
- Warranty:
- 18 months
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View