Schneider Electric HGA36060U33X Molded Case Circuit Breaker 600V 60A
Schneider Electric
$1,939.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2S trip unit and an LSI function with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Height:
- 163 mm
- Utilisation Category:
- category A
- Width:
- 104 mm
- Range:
- PowerPact
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Suitability For Isolation:
- yes IEC 60947-2
- Sustainable Offer Status:
- Green Premium product
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Mounting Mode:
- I-Line bracket)
- Ambient Air Temperature For Operation:
- -2-70 °C
- Warranty:
- 18 months
- Pvc Free:
- Yes
- Product Name:
- PowerPact H
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.2 S, LSI
- Terminal Identifier:
- AL150HD
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Circularity Profile:
- ENVEOLI2206028EN
- Mercury Free:
- Yes
- Product Or Component Type:
- circuit breaker
- Phase Connection:
- ABC
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Mounting Height:
- 4.5 in
- Pollution Degree:
- 3 IEC 60947-1
- Device Application:
- distribution
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Environmental Disclosure:
- ENVPEP2206028EN
- Poles Description:
- 3P
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Circuit Breaker Application:
- HACR rated
- Mounting Support:
- bracket
- Trip Unit Name:
- MicroLogic 3.2 S
- Communication Interface:
- Modbus || Ethernet
- Wire Stripping Length:
- 16 mm
- Breaking Capacity Code:
- G
- Control Type:
- toggle
- Eu Rohs Directive:
- Compliant with Exemptions
- Quantity Per Set:
- 1
- Product Certifications:
- UL || CSA || NOM
- Quality Labels:
- CE
- Protected Poles Description:
- 3t
- Line Rated Current:
- 60-60 A
- Rohs Exemption Information:
- Yes
- Net Weight:
- 2.2 kg
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Continuous Current Rating:
- 0.8
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Electrical Connection:
- I-Line connection, line || lugs, load
- Network Frequency:
- 50/60 Hz
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Depth:
- 86 mm
- Color:
- Black
- Ambient Air Temperature For Storage:
- -50-85 °C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View