Schneider Electric

Schneider Electric HGL36150M38X Motor circuit protector, PowerPacT H, 150A, 3 pole, 600VAC, 18kA, lugs, Micrologic 2.2M, 80%

(No reviews yet) Write a Review
SKU:
HGL36150M38X
MPN:
HGL36150M38X
Condition:
New
Color:
Black
Network Frequency:
50/60 Hz
Poles Description:
3P
Height:
163 mm
Net Weight:
2.2 kg
Trip Unit Technology:
electronic, standard, MicroLogic 2.2 M, LSoI
Trip Unit Name:
MicroLogic 2.2 M
Circularity Profile:
ENVEOLI2206027EN
Eu Rohs Directive:
Compliant with Exemptions
Mounting Mode:
unit mount lug)
Quality Labels:
CE
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Utilisation Category:
category A
Ambient Air Temperature For Storage:
-50-85°C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Warranty:
18 months
Protected Poles Description:
3t
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Line Rated Current:
150-150 A
Control Type:
toggle
Product Or Component Type:
Motor Circuit Protector
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Sustainable Offer Status:
Green Premium product
Depth:
86 mm
Mounting Support:
lug
Ambient Air Temperature For Operation:
-25-70°C
Pvc Free:
Yes
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Ip Degree Of Protection:
front cover IP40 IEC 60529
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Electrical Connection:
lugs, line || lugs, load
[Ith] Conventional Free Air Thermal Current:
58-130 A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Continuous Current Rating:
0.8
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Communication Interface:
Modbus || Ethernet
Environmental Disclosure:
ENVPEP2206027EN
Rohs Exemption Information:
Yes
Weight:
2.2 kg
Product Name:
PowerPact H
Wire Stripping Length:
16 mm
Device Application:
distribution
Breaking Capacity Code:
G
Product Certifications:
UL || CSA || NOM
Mercury Free:
Yes
Country of Origin:
United States
$2,701.00

Description

PowerPacT H-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. Additionally, Micrologic 2.2M trip units provide thermal protection for overload and phase unbalance. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. This PowerPacT H, 150A, 3 pole, motor protector has a breaking capacity of 18kA at 600VAC. This unit has lugs on both the line and load side. These motor protectors accept the same accessories and terminals as PowerPacT H circuit breakers. This breaker has a continuous current rating of 80%. PowerPacT H motor circuit protectors comply to UL, CSA, and IEC standards and are CE marked.
View AllClose