Schneider Electric HJL36125 Molded Case Circuit Breaker 600V 125A
Schneider Electric
$5,174.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Magnetic Tripping Current:
- 1700-1700 A
- Eu Rohs Directive:
- Compliant with Exemptions
- Electrical Connection:
- lugs, line || lugs, load
- Terminal Identifier:
- AL150HD
- Sustainable Offer Status:
- Green Premium product
- Breaking Capacity Code:
- J
- Quality Labels:
- CE
- Width:
- 104 mm
- Utilisation Category:
- category A
- Depth:
- 86 mm
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Quantity Per Set:
- 1
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Height:
- 163 mm
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Device Application:
- distribution
- Warranty:
- 18 months
- Circularity Profile:
- ENVEOLI2206027EN
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Communication Interface:
- Modbus || Ethernet
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Mercury Free:
- Yes
- Line Rated Current:
- 125-125 A
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Environmental Disclosure:
- ENVPEP2206027EN
- Trip Unit Technology:
- thermal-magnetic
- Color:
- Black
- Poles Description:
- 3P
- Control Type:
- toggle
- Product Certifications:
- UL || CSA || NOM
- Product Name:
- PowerPact H
- Suitability For Isolation:
- yes IEC 60947-2
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Pvc Free:
- Yes
- Net Weight:
- 2.2 kg
- Rohs Exemption Information:
- Yes
- Range:
- PowerPact
- Continuous Current Rating:
- 0.8
- Network Frequency:
- 50/60 Hz
- Circuit Breaker Application:
- HACR rated
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Mounting Mode:
- unit mount lug)
- Ambient Air Temperature For Storage:
- -50-85 °C
- Ambient Air Temperature For Operation:
- -2-70 °C
- Magnetic Hold Current:
- 900 A
- Protected Poles Description:
- 3t
- Mounting Support:
- lug
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Pollution Degree:
- 3 IEC 60947-1
- Wire Stripping Length:
- 16 mm
- Product Or Component Type:
- circuit breaker
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View