Schneider Electric HJL36125SA Molded Case Circuit Breaker 600V 125A

(No reviews yet) Write a Review
SKU:
HJL36125SA
UPC:
785901669173
Condition:
New
Wire Stripping Length:
16 mm
Height:
163 mm
Breaking Capacity Code:
J
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Line Rated Current:
125-125 A
Width:
104 mm
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Operation:
-2-70 °C
Ambient Air Temperature For Storage:
-50-85 °C
Trip Unit Technology:
thermal-magnetic
Warranty:
18 months
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Electrical Connection:
lugs, line || lugs, load
Net Weight:
2.2 kg
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Utilisation Category:
category A
Quantity Per Set:
1
Color:
Black
Suitability For Isolation:
yes IEC 60947-2
Product Certifications:
UL || CSA || NOM
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Mounting Support:
lug
Local Signalling:
switched off (OFF) 1 trip indicator green)
Product Or Component Type:
circuit breaker
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Depth:
86 mm
Environmental Disclosure:
ENVPEP2206027EN
Network Frequency:
50/60 Hz
Mercury Free:
Yes
Circularity Profile:
ENVEOLI2206027EN
Magnetic Tripping Current:
1700-1700 A
Eu Rohs Directive:
Compliant with Exemptions
Pvc Free:
Yes
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Range:
PowerPact
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Communication Interface:
Modbus || Ethernet
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Continuous Current Rating:
0.8
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quality Labels:
CE
Device Application:
distribution
Magnetic Hold Current:
900 A
Circuit Breaker Application:
HACR rated
Rohs Exemption Information:
Yes
Terminal Identifier:
AL150HD
Control Type:
toggle
Sustainable Offer Status:
Green Premium product
Mounting Mode:
unit mount lug)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Product Name:
PowerPact H
Ip Degree Of Protection:
front cover IP40 IEC 60529
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Protected Poles Description:
3t
Poles Description:
3P
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
$5,891.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose