Schneider Electric HLA36100U31X Molded Case Circuit Breaker 600V 100A

(No reviews yet) Write a Review
SKU:
HLA36100U31X
UPC:
3.60649E+12
Condition:
New
Rohs Exemption Information:
Yes
Terminal Identifier:
AL150HD
Utilisation Category:
category A
Breaking Capacity Code:
L
Pollution Degree:
3 IEC 60947-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Width:
104 mm
Wire Stripping Length:
16 mm
Circularity Profile:
ENVEOLI2206028EN
Environmental Disclosure:
ENVPEP2206028EN
Mounting Support:
bracket
Magnetic Tripping Current:
1700-1700 A
Circuit Breaker Application:
HACR rated
Depth:
86 mm
Product Name:
PowerPact H
Range:
PowerPact
Ambient Air Temperature For Operation:
-2-70 °C
Continuous Current Rating:
0.8
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Mercury Free:
Yes
Mounting Height:
4.5 in
Net Weight:
2.2 kg
Pvc Free:
Yes
Suitability For Isolation:
yes IEC 60947-2
Product Certifications:
UL || CSA || NOM
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Sustainable Offer Status:
Green Premium product
Network Frequency:
50/60 Hz
Communication Interface:
Modbus || Ethernet
Protected Poles Description:
3t
Long Time Pick-Up Adjustment Range:
0.25...1 x In
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Quantity Per Set:
1
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mounting Mode:
I-Line bracket)
Phase Connection:
ABC
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Line Rated Current:
100-100 A
Color:
Black
Trip Unit Technology:
electronic, standard, MicroLogic 3.2, LI
Ambient Air Temperature For Storage:
-50-85 °C
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Device Application:
distribution
Electrical Connection:
I-Line connection, line || lugs, load
Quality Labels:
CE
Trip Unit Name:
MicroLogic 3.2
Product Or Component Type:
circuit breaker
Control Type:
toggle
Ip Degree Of Protection:
front cover IP40 IEC 60529
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Warranty:
18 months
Poles Description:
3P
Magnetic Hold Current:
900 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Height:
163 mm
  • Schneider Electric HLA36100U31X Molded Case Circuit Breaker 600V 100A
  • Schneider Electric HLA36100U31X Molded Case Circuit Breaker 600V 100A
$3,490.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose