Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Utilisation Category:
category A
Quality Labels:
CE
Device Application:
distribution
Communication Interface:
Modbus || Ethernet
Product Certifications:
UL || CSA || NOM
Suitability For Isolation:
yes IEC 60947-2
Mounting Height:
4.5 in
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mounting Mode:
I-Line bracket)
Ip Degree Of Protection:
front cover IP40 IEC 60529
Circuit Breaker Application:
HACR rated
Quantity Per Set:
1
Phase Connection:
ABC
Circularity Profile:
ENVEOLI2206027EN
Magnetic Hold Current:
900 A
Terminal Identifier:
AL150HD
Trip Unit Technology:
thermal-magnetic
Poles Description:
3P
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Storage:
-50-85 °C
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Width:
104 mm
Breaking Capacity Code:
L
Rohs Exemption Information:
Yes
Line Rated Current:
125-125 A
Continuous Current Rating:
0.8
Mounting Support:
bracket
Mercury Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Magnetic Tripping Current:
1700-1700 A
Electrical Connection:
I-Line connection, line || lugs, load
Product Name:
PowerPact H
Protected Poles Description:
3t
Range:
PowerPact
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Pvc Free:
Yes
Product Or Component Type:
circuit breaker
Environmental Disclosure:
ENVPEP2206027EN
Sustainable Offer Status:
Green Premium product
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Network Frequency:
50/60 Hz
Wire Stripping Length:
16 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Local Signalling:
switched off (OFF) 1 trip indicator green)
Height:
163 mm
Control Type:
toggle
Warranty:
18 months
Net Weight:
2.2 kg
Depth:
86 mm
Color:
Black
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HLA36125 Molded Case Circuit Breaker 600V 125A
  • Schneider Electric HLA36125 Molded Case Circuit Breaker 600V 125A
  • Schneider Electric HLA36125 Molded Case Circuit Breaker 600V 125A
$6,951.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose