Schneider Electric HLA36150 Molded Case Circuit Breaker 600V 150A

(No reviews yet) Write a Review
SKU:
HLA36150
UPC:
7.85901E+11
Condition:
New
Height:
163 mm
Poles Description:
3P
Pollution Degree:
3 IEC 60947-1
Communication Interface:
Modbus || Ethernet
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Utilisation Category:
category A
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Color:
Black
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Offer Status:
Green Premium product
Electrical Connection:
I-Line connection, line || lugs, load
Continuous Current Rating:
0.8
Circuit Breaker Application:
HACR rated
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Device Application:
distribution
Eu Rohs Directive:
Compliant with Exemptions
Ip Degree Of Protection:
front cover IP40 IEC 60529
Ambient Air Temperature For Operation:
-2-70 °C
Range:
PowerPact
Ambient Air Temperature For Storage:
-50-85 °C
Magnetic Tripping Current:
1700-1700 A
Protected Poles Description:
3t
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP2206027EN
Depth:
86 mm
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Wire Stripping Length:
16 mm
Pvc Free:
Yes
Rohs Exemption Information:
Yes
Phase Connection:
ABC
Product Certifications:
UL || CSA || NOM
Mounting Mode:
I-Line bracket)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Local Signalling:
switched off (OFF) 1 trip indicator green)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mounting Height:
4.5 in
Line Rated Current:
150-150 A
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Suitability For Isolation:
yes IEC 60947-2
Mounting Support:
bracket
Breaking Capacity Code:
L
Quality Labels:
CE
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Terminal Identifier:
AL150HD
Control Type:
toggle
Magnetic Hold Current:
900 A
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Warranty:
18 months
Product Name:
PowerPact H
Circularity Profile:
ENVEOLI2206027EN
Network Frequency:
50/60 Hz
Width:
104 mm
Product Or Component Type:
circuit breaker
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Quantity Per Set:
1
Net Weight:
2.2 kg
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HLA36150 Molded Case Circuit Breaker 600V 150A
  • Schneider Electric HLA36150 Molded Case Circuit Breaker 600V 150A
$6,951.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.