Schneider Electric HMIZMDARX Multidisplay Adaptor For Gtu
Schneider Electric
$838.69
Multi Display Adapter for Harmony GTU
- Output Current:
- 50 mA
- Accessory / Separate Part Type:
- adaptor
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Input Voltage:
- 12 V DC module supply || 24 V DC
- Mercury Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Product Compatibility:
- Harmony GTU open || Harmony iPC industrial PCs
- Accessory / Separate Part Category:
- adaptation accessory
- Rohs Exemption Information:
- Yes
- Net Weight:
- 0.8 kg
- [Us] Rated Supply Voltage:
- 12 V DC module supply
- Reach Free Of Svhc:
- Yes
- Ambient Air Temperature For Operation:
- 0-60 °C
- Electromagnetic Compatibility:
- electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
- China Rohs Regulation:
- X
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Output Voltage Type:
- DC
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Relative Humidity:
- 10-90 % non-condensing
- Accessory / Separate Part Destination:
- Harmony GTU display
- Type Of Cooling:
- natural
- Output Voltage:
- 24 V
- Ambient Air Temperature For Storage:
- -20-60 °C
- Operating Altitude:
- 6561.68 ft (2000 m)
- Power Consumption In W:
- 8 W
- Shock Resistance:
- 147 m/s²X, Y, Z directions for 3 times EN/IEC 61131-2
- Pollution Degree:
- 2
- Vibration Resistance:
- 3.5 mm constant amplitude 5-9 Hz) X, Y, Z directions for 10 cycles (approx. 100 min) EN/IEC 61131-2 || 9.8 m/s² constant acceleration 9-150 Hz) X, Y, Z directions for 10 cycles (approx. 100 min) EN/IEC 61131-2
- Width:
- 188 mm
- Product Certifications:
- UL 508 || CSA C22-2 No 142 || CSA C22-2 No 213 || cULus HazLoc Class I Division 2 ANSI/ISA 12-12-01 || IEC-Ex || ATEX zone 2/22 || EAC || UKCA || UKEX
- Environmental Characteristic:
- corrosive gas free || dustproof
- Local Signalling:
- LED green, steady operating status (RUN) || LED green, faded stand-by || LED green/orange, alternate program mode || LED orange, flashing establishing communication connection || LED red, steady power ON || LED green, orange and red, alternate ERROR
- Resistance To Fast Transients:
- 1 kV IEC 61000-4-4 signal ports) || 2 kV IEC 61000-4-4 power ports)
- Height:
- 131 mm
- Depth:
- 35 mm
- Integrated Connection Type:
- 1 DIO terminal block 3 inputs + 1 output || 2 Ethernet TCP/IP RJ45 jack
- Range Of Product:
- Harmony GTU
- Catalog:
- View
- Datasheet: