Schneider Electric JDA261752 Molded Case Circuit Breaker 600V 175A
Schneider Electric
$3,424.50
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT J I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 175A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Magnetic Tripping Current:
- 1750-1750 A
- Net Weight:
- 2.4 kg
- Mounting Support:
- bracket
- Mounting Mode:
- I-Line bracket)
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Sustainable Offer Status:
- Green Premium product
- Phase Connection:
- AC
- Pollution Degree:
- 3
- Height:
- 191 mm
- Depth:
- 86 mm
- Continuous Current Rating:
- 0.8
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Eu Rohs Directive:
- Compliant with Exemptions
- Control Type:
- toggle
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Product Or Component Type:
- circuit breaker
- Suitability For Isolation:
- yes IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Product Certifications:
- UL || CSA || NOM
- Ambient Air Temperature For Storage:
- -50-85 °C
- Magnetic Hold Current:
- 875 A
- Mounting Height:
- 4.5 in
- Circuit Breaker Application:
- HACR rated
- Mercury Free:
- Yes
- Terminal Identifier:
- AL175JD
- Quality Labels:
- CE
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Rohs Exemption Information:
- Yes
- Pvc Free:
- Yes
- Ip Degree Of Protection:
- front cover IP40
- Environmental Disclosure:
- ENVPEP2206031EN
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Line Rated Current:
- 175-175 A
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Utilisation Category:
- category A
- Communication Interface:
- Modbus
- Protection Type:
- overload protection || short-circuit protection
- Electrical Connection:
- I-Line connection, line || lugs, load
- Breaking Capacity Code:
- D
- Trip Unit Technology:
- thermal-magnetic
- Circularity Profile:
- ENVEOLI2206031EN
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Wire Stripping Length:
- 25 mm
- Poles Description:
- 2P
- Tightening Torque:
- 25-25 N.m 25-95 mm² (AWG 4...AWG 4/0)
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Awg Gauge:
- AWG 4...AWG 4/0 aluminium/copper terminal
- Width:
- 104 mm
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View