Schneider Electric JDM36200C Molded Case Circuit Breaker 600V 200A
Schneider Electric
$3,276.00
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on the line side and terminal nuts on the load side. This PowerPacT J, 200A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Mounting Height:
- 4.5 in
- Suitability For Isolation:
- yes IEC 60947-2
- Range:
- PowerPact
- Protection Type:
- overload protection || short-circuit protection
- [Ith] Conventional Free Air Thermal Current:
- 114-217 A
- Ambient Air Temperature For Storage:
- -50-85 °C
- Line Rated Current:
- 200-200 A
- Rohs Exemption Information:
- Yes
- Network Frequency:
- 50/60 Hz
- Poles Description:
- 3P
- Height:
- 191 mm
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Sustainable Offer Status:
- Green Premium product
- Product Name:
- PowerPact J
- Mercury Free:
- Yes
- Utilisation Category:
- category A
- Communication Interface:
- Modbus || Ethernet
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Quality Labels:
- CE
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Magnetic Hold Current:
- 1000 A
- Device Application:
- distribution
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Breaking Capacity Code:
- D
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40
- Pollution Degree:
- 3 IEC 60947-1
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Depth:
- 86 mm
- Width:
- 104 mm
- Ambient Air Temperature For Operation:
- -2-70 °C
- Environmental Disclosure:
- ENVPEP2206031EN
- Circularity Profile:
- ENVEOLI2206031EN
- Eu Rohs Directive:
- Compliant with Exemptions
- Product Certifications:
- UL || CSA || NOM
- Mounting Support:
- lug
- Warranty:
- 18 months
- Continuous Current Rating:
- 1
- Net Weight:
- 2.4 kg
- Phase Connection:
- ABC
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Wire Stripping Length:
- 25 mm
- Pvc Free:
- Yes
- Product Or Component Type:
- Motor Circuit Protector
- Control Type:
- toggle
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Electrical Connection:
- lugs, line || terminal nut, load
- Magnetic Tripping Current:
- 2000-2000 A
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Mounting Mode:
- unit mount lug)
- Trip Unit Technology:
- thermal-magnetic
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Terminal Identifier:
- AL250JD
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View