Schneider Electric JJA36250 Molded Case Circuit Breaker 600V 250A

(No reviews yet) Write a Review
SKU:
JJA36250
UPC:
785901689881
Condition:
New
Pollution Degree:
3 IEC 60947-1
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Or Component Type:
circuit breaker
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Width:
104 mm
Net Weight:
2.4 kg
Ambient Air Temperature For Operation:
-2-70 °C
Product Certifications:
UL || CSA || NOM
Phase Connection:
ABC
Magnetic Hold Current:
1250 A
Utilisation Category:
category A
Communication Interface:
Modbus || Ethernet
Breaking Capacity Code:
J
Depth:
86 mm
Magnetic Tripping Current:
2500-2500 A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Protection Type:
overload protection || short-circuit protection
Height:
191 mm
Sustainable Offer Status:
Green Premium product
Network Frequency:
50/60 Hz
Eu Rohs Directive:
Compliant with Exemptions
Local Signalling:
switched off (OFF) 1 trip indicator green)
Mounting Support:
bracket
Mounting Mode:
I-Line bracket)
Mounting Height:
4.5 in
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Wire Stripping Length:
25 mm
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Range:
PowerPact
Terminal Identifier:
AL250JD
Electrical Connection:
I-Line connection, line || lugs, load
Ip Degree Of Protection:
front cover IP40
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pvc Free:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Circuit Breaker Application:
HACR rated
Control Type:
toggle
Product Name:
PowerPact J
Continuous Current Rating:
0.8
Trip Unit Technology:
thermal-magnetic
Rohs Exemption Information:
Yes
Warranty:
18 months
Mercury Free:
Yes
Circularity Profile:
ENVEOLI2206031EN
Environmental Disclosure:
ENVPEP2206031EN
Quality Labels:
CE
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Line Rated Current:
250-250 A
Suitability For Isolation:
yes IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Device Application:
distribution
Ambient Air Temperature For Storage:
-50-85 °C
Poles Description:
3P
$7,599.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT J I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 250A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose