Schneider Electric LC1D1156M7 IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style
Schneider Electric
$479.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Signaling Circuit Frequency:
- 25...400 Hz
- Pollution Degree:
- 3
- Net Weight:
- 2.5 kg
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
- Pvc Free:
- Yes
- Control Circuit Voltage Limits:
- 0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
- Device Short Name:
- LC1D
- Heat Dissipation:
- 3-8 W at 50/60 Hz
- Associated Fuse Rating:
- 250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit
- [Uc] Control Circuit Voltage:
- 220 V AC 50/60 Hz
- Maximum Operating Rate:
- 2400 cyc/h 60°C
- Fire Resistance:
- 850°C IEC 60695-2-1
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
- [Ue] Rated Operational Voltage:
- power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
- Hold-In Power Consumption In Va:
- 2-18 VA 60 Hz cos phi 0.3 (at 20°C) || 2-18 VA 50 Hz cos phi 0.3 (at 20°C)
- Protective Cover:
- with
- Minimum Switching Current:
- 5 mA for Signaling circuit
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Motor Power Kw:
- 30 kW at 220...230 V AC 50/60 Hz (AC-3) || 55 kW at 380...400 V AC 50/60 Hz (AC-3) || 59 kW at 415...440 V AC 50/60 Hz (AC-3) || 75 kW at 500 V AC 50/60 Hz (AC-3) || 80 kW at 660...690 V AC 50/60 Hz (AC-3) || 65 kW at 1000 V AC 50/60 Hz (AC-3) || 18.
- Width:
- 120 mm
- Inrush Power In Va:
- 280-350 VA 60 Hz cos phi 0.8 (at 20°C) || 280-350 VA 50 Hz cos phi 0.8 (at 20°C)
- Protective Treatment:
- THIEC 60068-2-30
- Flame Retardance:
- V1 conforming to UL 94
- Circularity Profile:
- ENVEOLI100405EN
- Operating Time:
- 6...20 ms opening || 20...50 ms closing
- Rohs Exemption Information:
- Yes
- Product Or Component Type:
- contactor
- Average Impedance:
- 0.6 mOhm - Ith 200 A 50 Hz for power circuit
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Contactor Application:
- motor control || resistive load
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Product Certifications:
- UL || CSA || CCC || UKCA || CE || EAC || Marine
- Warranty:
- 18 months
- Environmental Disclosure:
- ENVPEP060301EN
- Irms Rated Making Capacity:
- 1260 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Mechanical Durability:
- 8 Mcycles
- Poles Description:
- 3P
- Maximum Horse Power Rating:
- 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- Country of Origin:
- Czechia
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Range:
- TeSys
- [Icw] Rated Short-Time Withstand Current:
- 250 A 40°C - 10 min for power circuit || 550 A 40°C - 1 min for power circuit || 950 A 40°C - 10 s for power circuit || 1100 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- Connections - Terminals:
- control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 25 mm || power circuit: bars 1 - busbar cross section: 5 x 25 mm