TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200 to 208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.90 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.72 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 16 A (at 60°C) for power circuit
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Overvoltage Category:
- III
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Operating Time:
- 12...22 ms closing || 4...19 ms opening
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Contactor Application:
- resistive load || motor control
- Range Of Product:
- TeSys Deca
- Eu Rohs Directive:
- Compliant
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Electrical Durability:
- 2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 12 A AC-3e <= 440 V
- [Icw] Rated Short-Time Withstand Current:
- 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Height:
- 99 mm
- Maximum Horse Power Rating:
- 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 460/480 V AC 50/60 Hz for 3 phase
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Product Or Component Type:
- contactor
- Mercury Free:
- Yes
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Ie] Rated Operational Current:
- 16 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Country of Origin:
- United States
- Poles Description:
- 3P
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Power Dissipation Per Pole:
- 0.36 W AC-3 || 1.56 W AC-1 || 0.36 W AC-3e
- Minimum Switching Current:
- 5 mA for Signaling circuit
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Flame Retardance:
- V1 conforming to UL 94
- Protective Cover:
- with
- Rohs Exemption Information:
- Yes
- Pvc Free:
- Yes
- Environmental Disclosure:
- ENVPEP1501004
- Protective Treatment:
- THIEC 60068-2-30
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Pole Contact Composition:
- 3 NO
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Toxic Heavy Metal Free:
- Yes
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Pollution Degree:
- 3
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Connections - Terminals:
- power circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 1 2.5-2.5 mm² - cable s
- Control Circuit Type:
- AC 50/60 Hz
- Product Certifications:
- GL || BV || DNV || LROS (Lloyds register of shipping) || RINA || UL || CCC || CSA || GOST || UKCA || CB
- Coil Technology:
- without built-in suppressor module