Schneider Electric

Schneider Electric LC1D123P7 IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, 3 phase, 3 pole, 3 NO, 230VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D123P7
MPN:
LC1D123P7
Condition:
New
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Pole Contact Composition:
3 NO
Operating Time:
12...22 ms closing || 4...19 ms opening
Depth:
86 mm
Connections - Terminals:
power circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 1 2.5-2.5 mm² - cable s
Operating Altitude:
0...9842.52 ft (0...3000 m)
Height:
99 mm
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Utilisation Category:
AC-3 || AC-4 || AC-1 || AC-3e
[Ie] Rated Operational Current:
16 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Control Circuit Type:
AC 50/60 Hz
Signaling Circuit Frequency:
25...400 Hz
Flame Retardance:
V1 conforming to UL 94
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Poles Description:
3P
Product Certifications:
LROS (Lloyds register of shipping) || GL || BV || UL || CSA || CCC || DNV || RINA || GOST || UKCA
Eu Rohs Directive:
Compliant
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Minimum Switching Voltage:
17 V for Signaling circuit
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Fire Resistance:
850°C IEC 60695-2-1
Pvc Free:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
Product Or Component Type:
contactor
Environmental Disclosure:
ENVPEP1501004
Power Dissipation Per Pole:
0.36 W AC-3 || 1.56 W AC-1 || 0.36 W AC-3e
Warranty:
18 months
Overvoltage Category:
III
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 16 A (at 60°C) for power circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Circularity Profile:
ENVEOLI1501004
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Coil Technology:
without built-in suppressor module
Compatibility Code:
LC1D
Ip Degree Of Protection:
IP20 front face IEC 60529
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Motor Power Kw:
3 kW at 220...230 V AC 50/60 Hz (AC-3) || 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 5.5 kW at 415 V AC 50/60 Hz (AC-3) || 5.5 kW at 440 V AC 50/60 Hz (AC-3) || 7.5 kW at 500 V AC 50/60 Hz (AC-3) || 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 3 kW a
Width:
45 mm
Sustainable Offer Status:
Green Premium product
Average Impedance:
2.5 mOhm - Ith 16 A 50 Hz for power circuit
Minimum Switching Current:
5 mA for Signaling circuit
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Heat Dissipation:
2-3 W at 50/60 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Toxic Heavy Metal Free:
Yes
Pollution Degree:
3
Net Weight:
0.325 kg
Rohs Exemption Information:
Yes
$142.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200 to 208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.90 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.72 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.