Schneider Electric

Schneider Electric LC1D128U7 IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 2 NO and 2 NC, 240VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D128U7
MPN:
LC1D128U7
Condition:
New
Warranty:
18 months
Mechanical Durability:
15 Mcycles
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Pollution Degree:
3
Control Circuit Type:
AC 50/60 Hz
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP1501004
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile:
ENVEOLI1501004
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Overvoltage Category:
III
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Rohs Exemption Information:
Yes
Heat Dissipation:
2-3 W at 50/60 Hz
Weight:
0.365 kg
Product Certifications:
GOST || GL || RINA || LROS (Lloyds register of shipping) || CSA || BV || CCC || UL || DNV || UKCA
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Fire Resistance:
850°C IEC 60695-2-1
Ip Degree Of Protection:
IP20 front face IEC 60529
[Ith] Conventional Free Air Thermal Current:
25 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Range Of Product:
TeSys Deca
Minimum Switching Current:
5 mA for Signaling circuit
Protective Treatment:
THIEC 60068-2-30
Eu Rohs Directive:
Compliant
Coil Technology:
without built-in suppressor module
Toxic Heavy Metal Free:
Yes
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Mercury Free:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Contactor Application:
resistive load
Product Or Component Type:
contactor
[Uc] Control Circuit Voltage:
240 V AC 50/60 Hz
Insulation Resistance:
> 10 MOhm for Signaling circuit
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate:
3600 cyc/h 60°C
Operating Altitude:
0...9842.52 ft (0...3000 m)
Pole Contact Composition:
2 NO + 2 NC
$165.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose