Schneider Electric

Schneider Electric LC1D188P7 IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D188P7
MPN:
LC1D188P7
Condition:
New
Protective Treatment:
THIEC 60068-2-30
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
Average Impedance:
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Signaling Circuit Frequency:
25...400 Hz
Fire Resistance:
850°C IEC 60695-2-1
Auxiliary Contact Composition:
1 NO + 1 NC
Power Dissipation Per Pole:
2.5 W AC-1
Device Short Name:
LC1D
Mercury Free:
Yes
Operating Altitude:
0...9842.52 ft (0...3000 m)
Rated Breaking Capacity:
300 A at 440 V for power circuit conforming to IEC 60947
Heat Dissipation:
2-3 W at 50/60 Hz
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.8 N.m screw clamps terminals flat Ø 6 mm || po
Protective Cover:
with
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
[Ie] Rated Operational Current:
32 A (at <60°C) at <= 440 V AC AC-1 for power circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Mounting Support:
rail || plate
Compatibility Code:
LC1D
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Type:
AC 50/60 Hz
Range Of Product:
TeSys Deca
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Mechanical Durability:
15 Mcycles
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Voltage:
17 V for Signaling circuit
Pvc Free:
Yes
Warranty:
18 months
Circularity Profile:
ENVEOLI1501004
Maximum Operating Rate:
3600 cyc/h 60°C
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Minimum Switching Current:
5 mA for Signaling circuit
Coil Technology:
without built-in suppressor module
Height:
91 mm
Electrical Durability:
1 Mcycles 32 A AC-1 <= 440 V
Overvoltage Category:
III
Contactor Application:
resistive load
Operating Time:
12...22 ms closing || 4...19 ms opening
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Insulation Resistance:
> 10 MOhm for Signaling circuit
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant
$194.40

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 32A resistive load rating. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.13 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.