Schneider Electric

Schneider Electric LC1D18ED IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48VDC coil, open

(No reviews yet) Write a Review
SKU:
LC1D18ED
MPN:
LC1D18ED
Condition:
New
Mechanical Durability:
30 Mcycles
Coil Technology:
with integral suppression device
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
Protective Cover:
with
Warranty:
18 months
Insulation Resistance:
> 10 MOhm for Signaling circuit
Weight:
0.49 kg
Flame Retardance:
V1 conforming to UL 94
Protective Treatment:
THIEC 60068-2-30
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Product Or Component Type:
contactor
Motor Power Kw:
4 kW at 220...230 V AC 50/60 Hz (AC-3) || 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 9 kW at 415...440 V AC 50/60 Hz (AC-3) || 10 kW at 500 V AC 50/60 Hz (AC-3) || 10 kW at 660...690 V AC 50/60 Hz (AC-3) || 4 kW at 400 V AC 50/60 Hz (AC-4) || 4 kW a
Pole Contact Composition:
3 NO
Average Impedance:
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Contactor Application:
motor control || resistive load
Minimum Switching Current:
5 mA for Signaling circuit
Pollution Degree:
3
[Ie] Rated Operational Current:
18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Pvc Free:
Yes
Poles Description:
3P
Overvoltage Category:
III
Maximum Operating Rate:
3600 cyc/h 60°C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
77 mm
Maximum Horse Power Rating:
1 hp at 115 V AC 50/60 Hz for 1 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 10 hp at 460/480 V AC 50/60 Hz for 3 phase mot
Inrush Power In W:
5.4-5.4 W 20°C)
Electrical Durability:
1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V || 1.65 Mcycles 18 A AC-3e <= 440 V
Sustainable Offer Status:
Green Premium product
Depth:
95 mm
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Eu Rohs Directive:
Compliant with Exemptions
Compatibility Code:
LC1D
[Icw] Rated Short-Time Withstand Current:
145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Net Weight:
0.49 kg
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Signaling Circuit Frequency:
25...400 Hz
Country of Origin:
France
Utilisation Category:
AC-3 || AC-1 || AC-4 || AC-3e
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Rohs Exemption Information:
Yes
Operating Time:
63±15 % ms closing || 20±20 % ms opening
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Environmental Disclosure:
ENVPEP110230EN
Product Certifications:
GL || BV || DNV || LROS (Lloyds register of shipping) || RINA || UL || CCC || CSA || GOST || UKCA || CB
Control Circuit Type:
DC standard
$170.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 48 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.08 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose