Schneider Electric

Schneider Electric LC1D18G7 IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D18G7
MPN:
LC1D18G7
Condition:
New
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Depth:
86 mm
Electrical Durability:
1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V || 1.65 Mcycles 18 A AC-3e <= 440 V
Flame Retardance:
V1 conforming to UL 94
Range Of Product:
TeSys Deca
Product Certifications:
GL || BV || DNV || LROS (Lloyds register of shipping) || RINA || UL || CCC || CSA || GOST || UKCA || CB
Minimum Switching Voltage:
17 V for Signaling circuit
Eu Rohs Directive:
Compliant
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Country of Origin:
Indonesia
Toxic Heavy Metal Free:
Yes
Net Weight:
0.33 kg
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Signaling Circuit Frequency:
25...400 Hz
Utilisation Category:
AC-1 || AC-4 || AC-3 || AC-3e
Sustainable Offer Status:
Green Premium product
Width:
45 mm
Overvoltage Category:
III
[Ie] Rated Operational Current:
18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Poles Description:
3P
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Ip Degree Of Protection:
IP20 front face IEC 60529
Fire Resistance:
850°C IEC 60695-2-1
Heat Dissipation:
2-3 W at 50/60 Hz
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Rohs Exemption Information:
Yes
Minimum Switching Current:
5 mA for Signaling circuit
[Uc] Control Circuit Voltage:
120 V AC 50/60 Hz
Auxiliary Contact Composition:
1 NO + 1 NC
[Icw] Rated Short-Time Withstand Current:
145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Operating Altitude:
0...9842.52 ft (0...3000 m)
Motor Power Kw:
4 kW at 220...230 V AC 50/60 Hz (AC-3) || 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 9 kW at 415...440 V AC 50/60 Hz (AC-3) || 10 kW at 500 V AC 50/60 Hz (AC-3) || 10 kW at 660...690 V AC 50/60 Hz (AC-3) || 4 kW at 400 V AC 50/60 Hz (AC-4) || 4 kW a
Environmental Disclosure:
ENVPEP1501004
Warranty:
18 months
Power Dissipation Per Pole:
2.5 W AC-1 || 0.8 W AC-3 || 0.8 W AC-3e
Coil Technology:
without built-in suppressor module
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Product Or Component Type:
contactor
$163.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose