New
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Fire Resistance:
850°C IEC 60695-2-1
Mercury Free:
Yes
Operating Altitude:
0...9842.52 ft (0...3000 m)
Weight:
0.992 kg
Range Of Product:
TeSys Deca
Product Or Component Type:
contactor
Mounting Support:
plate || rail
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
Flame Retardance:
V1 conforming to UL 94
Protective Cover:
with
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Signaling Circuit Frequency:
25...400 Hz
Electrical Durability:
2 Mcycles 35 A AC-3 <= 440 V || 0.7 Mcycles 60 A AC-1 <= 440 V || 2 Mcycles 35 A AC-3e <= 440 V
Associated Fuse Rating:
80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Width:
55 mm
[Icw] Rated Short-Time Withstand Current:
72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Power Dissipation Per Pole:
5.4 W AC-1 || 2.4 W AC-3 || 2.4 W AC-3e
Ip Degree Of Protection:
IP20 front face IEC 60529
Warranty:
18 months
Hold-In Power Consumption In W:
1.2-1.2 W 20°C
Operating Time:
55...65 ms closing || 20...80 ms opening
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
Pole Contact Composition:
3 NO
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
[Ith] Conventional Free Air Thermal Current:
60 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Contactor Application:
resistive load || motor control
Country of Origin:
France
Connections - Terminals:
power circuit: lugs-ring terminals - external diameter: 16.5 mm || control circuit: lugs-ring terminals - external diameter: 8 mm
Poles Description:
3P
Range:
TeSys || TeSys Deca
Circularity Profile:
ENVEOLI1607010EN
Maximum Operating Rate:
3600 cyc/h 60°C
Irms Rated Making Capacity:
800 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4 |
Auxiliary Contact Composition:
1 NO + 1 NC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Heat Dissipation:
1.2-1.2 W at 50/60 Hz
Hold-In Power Consumption In Va:
1.8-1.8 VA 50/60 Hz (at 20°C)
Depth:
120 mm
Height:
122 mm
Coil Technology:
built-in bidirectional peak limiting
Inrush Power In Va:
18-18 VA 50/60 Hz (at 20°C)
$330.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.19 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose