Schneider Electric

Schneider Electric LC1D40AB7 IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D40AB7
MPN:
LC1D40AB7
Condition:
New
Fire Resistance:
850°C IEC 60695-2-1
Protective Treatment:
THIEC 60068-2-30
Rohs Exemption Information:
Yes
Utilisation Category:
AC-4 || AC-1 || AC-3 || AC-3e
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Operating Altitude:
0...9842.52 ft (0...3000 m)
Environmental Disclosure:
ENVPEP1503009EN
Maximum Operating Rate:
3600 cyc/h 60°C
Pole Contact Composition:
3 NO
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
[Uc] Control Circuit Voltage:
24 V AC 50/60 Hz
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Range Of Product:
TeSys Deca
Product Or Component Type:
contactor
Width:
55 mm
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Signaling Circuit Frequency:
25...400 Hz
Flame Retardance:
V1 conforming to UL 94
Auxiliary Contact Composition:
1 NO + 1 NC
Pollution Degree:
3
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Circularity Profile:
ENVEOLI1503009EN
Weight:
0.85 kg
Minimum Switching Voltage:
17 V for Signaling circuit
Control Circuit Type:
AC 50/60 Hz standard
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Sustainable Offer Status:
Green Premium product
Country of Origin:
United States
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Electrical Durability:
1.4 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Toxic Heavy Metal Free:
Yes
Net Weight:
0.85 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Pvc Free:
Yes
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application:
motor control || resistive load
Range:
TeSys || TeSys Deca
Depth:
120 mm
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Ip Degree Of Protection:
IP20 front face IEC 60529
Insulation Resistance:
> 10 MOhm for Signaling circuit
Mounting Support:
plate || rail
Mercury Free:
Yes
Operating Time:
4...19 ms opening || 12...26 ms closing
Compatibility Code:
LC1D
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
$261.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose