Schneider Electric

Schneider Electric LC1D40AEHE IEC contactor, TeSys Deca Green, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48/130VAC/VDC coil

(No reviews yet) Write a Review
SKU:
LC1D40AEHE
MPN:
LC1D40AEHE
Condition:
New
Mechanical Durability:
6 Mcycles
Utilisation Category:
AC-3 || AC-1 || AC-3e
Halogen Content Performance:
Halogen free plastic parts & cables product
Warranty:
18 months
Motor Power Kw:
11 kW at 220...230 V AC 50 Hz (AC-3) || 18.5 kW at 380...400 V AC 50 Hz (AC-3) || 22 kW at 415 V AC 50 Hz (AC-3) || 22 kW at 440 V AC 50 Hz (AC-3) || 22 kW at 500 V AC 50 Hz (AC-3) || 30 kW at 660...690 V AC 50 Hz (AC-3) || 11 kW at 220...230 V AC 50
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Associated Fuse Rating:
80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Eu Rohs Directive:
Compliant with Exemptions
Poles Description:
3P
Fire Resistance:
850°C IEC 60695-2-1
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Operating Altitude:
0...9842.52 ft (0...3000 m)
Inrush Power In W:
19-19 W 20°C)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Net Weight:
0.992 kg
Signaling Circuit Frequency:
25...400 Hz
Depth:
120 mm
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Maximum Operating Rate:
3600 cyc/h 60°C
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC-3e for power circuit
Sustainable Offer Status:
Green Premium product
Range Of Product:
TeSys Deca
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Flame Retardance:
V1 conforming to UL 94
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Icw] Rated Short-Time Withstand Current:
72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Ip Degree Of Protection:
IP20 front face IEC 60529
Range:
TeSys || TeSys Deca
Inrush Power In Va:
23-23 VA 50/60 Hz (at 20°C)
Hold-In Power Consumption In Va:
1.4-1.4 VA 50/60 Hz (at 20°C)
Mounting Support:
plate || rail
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Device Short Name:
LC1D
Power Dissipation Per Pole:
5.4 W AC-1 || 2.4 W AC-3 || 2.4 W AC-3e
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
[Ith] Conventional Free Air Thermal Current:
60 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Protective Cover:
with
Rohs Exemption Information:
Yes
Environmental Disclosure:
ENVPEP1607010EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
Country of Origin:
France
Minimum Switching Current:
5 mA for Signaling circuit
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Overvoltage Category:
III
$111.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.19 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose