Schneider Electric

Schneider Electric LC1D40G7 TeSys D IEC contactor, 40 A, 3 P, 30 HP at 480 VAC, nonreversing, 120 VAC 50/60 Hz coil

(No reviews yet) Write a Review
SKU:
LC1D40G7
MPN:
LC1D40G7
Condition:
New
Mercury Free:
Yes
Hold-In Power Consumption In Va:
13-13 VA 50 Hz cos phi 0.3 (at 20°C) || 15-15 VA 60 Hz cos phi 0.3 (at 20°C)
Mounting Support:
rail || plate
Connections - Terminals:
control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-2.5 mm² - cable s
Height:
127 mm
Insulation Resistance:
> 10 MOhm for control circuit
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Toxic Heavy Metal Free:
Yes
Standards:
UL 508 || IEC 60947-4-1 || CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-5-1 || EN 60947-5-1
Net Weight:
1.4 kg
Fire Resistance:
850°C IEC 60695-2-1
Protective Cover:
with
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Minimum Switching Current:
5 mA for control circuit
Eu Rohs Directive:
Compliant
Permissible Ambient Air Temperature Around The Device:
-5-60°C || -40-70°C at Uc
Weight:
1.4 kg
Mechanical Robustness:
shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
Reach Free Of Svhc:
Yes
Maximum Horse Power Rating:
10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA || 10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL || 10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA || 10 hp at 230/240 V AC 60 Hz for 3 phase motors
Country of Origin:
Czechia
Overvoltage Category:
III
Control Circuit Voltage Limits:
0.3...0.6 Uc 60-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc 60-60°C operational AC 50 Hz || 0.85...1.1 Uc 60-60°C operational AC 60 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Auxiliary Contact Composition:
1 NO + 1 NC
Contactor Application:
resistive load || motor control
Associated Fuse Rating:
10 A gG for control circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Operating Altitude:
9842.52 ft (3000 m) without derating
Depth:
119 mm
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Pole Contact Composition:
3 NO
Climatic Withstand:
IACS E10 exposure to damp heat
Maximum Operating Rate:
3600 cyc/h 60°C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Range:
TeSys
Motor Power Kw:
18.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 22 kW at 1000 V AC 50/60 Hz (AC-3) || 22 kW at 415 V AC 50/60 Hz (AC-3) || 22 kW at 440 V AC 50/60 Hz (AC-3) || 22 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 660...690 V AC 50/60 Hz (AC-3) || 11 kW at 220.
[Ui] Rated Insulation Voltage:
control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Circularity Profile:
N/A
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Product Or Component Type:
contactor
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 60 A (at 60°C) for power circuit
Control Circuit Type:
AC 50/60 Hz
[Uc] Control Circuit Voltage:
120 V AC 50/60 Hz
$361.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. They can be used to create motor starters for almost any type of application. TeSys D contactors offer quick simple setup, while maintaining a compact size. Contactors have both Horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications. Multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs/Reach).
View AllClose