Schneider Electric

Schneider Electric LC1D40T6 IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 480VAC 60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40T6
MPN:
LC1D40T6
Condition:
New
Auxiliary Contact Composition:
1 NO + 1 NC
Sustainable Offer Status:
Green Premium product
Product Certifications:
GL || BV || DNV || LROS (Lloyds register of shipping) || RINA || UL || CCC || CSA || GOST || UKCA || CB
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Rohs Exemption Information:
Yes
Standards:
UL 508 || EN 60947-5-1 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14
Country of Origin:
France
Hold-In Power Consumption In Va:
13-13 VA 50 Hz cos phi 0.3 (at 20°C) || 15-15 VA 60 Hz cos phi 0.3 (at 20°C)
Minimum Switching Current:
5 mA for control circuit
Irms Rated Making Capacity:
140 A AC for control circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Pvc Free:
Yes
Tightening Torque:
control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw clamp terminal flat Ø 6 mm || power circuit 5 N.m screw clamp terminal flat Ø 8 mm || control circui
Toxic Heavy Metal Free:
Yes
Associated Fuse Rating:
10 A gG for control circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Poles Description:
3P
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Mercury Free:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Maximum Horse Power Rating:
10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA || 10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL || 10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA || 10 hp at 230/240 V AC 60 Hz for 3 phase motors
Motor Power Kw:
18.5 kW at 380...400 V AC 50/60 Hz || 22 kW at 500 V AC 50/60 Hz || 30 kW at 660...690 V AC 50/60 Hz || 11 kW at 220...230 V AC 50/60 Hz || 22 kW at 1000 V AC 50/60 Hz || 22 kW at 415 V AC 50/60 Hz || 22 kW at 440 V AC 50/60 Hz
Inrush Power In Va:
140-140 VA cos phi 0.75 (at 20°C) || 160-160 VA cos phi 0.75 (at 20°C)
Control Circuit Voltage Limits:
0.85...1.1 Uc 60-60°C operational AC 60 Hz || 0.3...0.6 Uc 60-60°C drop-out AC 60 Hz
Minimum Switching Voltage:
17 V for control circuit
Pole Contact Composition:
3 NO
Weight:
1.4 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 60 A (at 60°C) for power circuit
Mechanical Robustness:
shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
Reach Free Of Svhc:
Yes
Operating Altitude:
9842.52 ft (3000 m) without derating
Utilisation Category:
AC-1 || AC-4 || AC-2 || AC-3 || AC-3e
Heat Dissipation:
4-5 W at 50/60 Hz for control circuit
Environmental Disclosure:
ENVPEP110205EN
[Uc] Control Circuit Voltage:
480 V AC 60 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Mounting Support:
rail || plate
Depth:
119 mm
Product Or Component Type:
contactor
Overvoltage Category:
III
[Ui] Rated Insulation Voltage:
control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Warranty:
18 months
Range:
TeSys
Net Weight:
1.4 kg
Insulation Resistance:
> 10 MOhm for control circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Flame Retardance:
V1 conforming to UL 94
Device Short Name:
LC1D
Range Of Product:
TeSys Deca
Width:
75 mm
$361.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 480 VAC50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose