Schneider Electric

Schneider Electric LC1D65AX7 IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 600VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D65AX7
MPN:
LC1D65AX7
Condition:
New
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
Warranty:
18 months
Fire Resistance:
850°C IEC 60695-2-1
Utilisation Category:
AC-1 || AC-4 || AC-3 || AC-3e
Auxiliary Contact Composition:
1 NO + 1 NC
Reach Regulation:
Free of Substances of Very High Concern above the threshold
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Country of Origin:
France
Control Circuit Type:
AC 50/60 Hz
Net Weight:
0.86 kg
Pvc Free:
Yes
Range Of Product:
TeSys Deca
Mounting Support:
plate || rail
Minimum Switching Current:
5 mA for Signaling circuit
Heat Dissipation:
4-5 W at 50/60 Hz
Height:
122 mm
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Electrical Durability:
1.4 Mcycles 80 A AC-1 <= 440 V || 1.45 Mcycles 65 A AC-3 <= 440 V || 1.45 Mcycles 65 A AC-3e <= 440 V
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Product Or Component Type:
contactor
Tightening Torque:
control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BT
Eu Rohs Directive:
Compliant
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Coil Technology:
without built-in suppressor module
Flame Retardance:
V1 conforming to UL 94
Toxic Heavy Metal Free:
Yes
Pollution Degree:
3
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Protective Treatment:
THIEC 60068-2-30
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Mechanical Durability:
6 Mcycles
Device Short Name:
LC1D
Minimum Switching Voltage:
17 V for Signaling circuit
Environmental Disclosure:
ENVPEP1503009EN
Operating Time:
4...19 ms opening || 12...26 ms closing
Reach Free Of Svhc:
Yes
Overvoltage Category:
III
Width:
55 mm
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Circularity Profile:
ENVEOLI1503009EN
Poles Description:
3P
Range:
TeSys
Ip Degree Of Protection:
IP20 front face IEC 60529
$444.36

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 600 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose