Schneider Electric

Schneider Electric LC1D80008G7 IEC contactor, TeSys Deca, nonreversing, 125A resistive, 4 pole, 2 NO and 2 NC, 120VAC 50/60Hz coil, open style, open style

(No reviews yet) Write a Review
SKU:
LC1D80008G7
MPN:
LC1D80008G7
Condition:
New
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Flame Retardance:
V1 conforming to UL 94
Associated Fuse Rating:
200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
Irms Rated Making Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Fire Resistance:
850°C IEC 60695-2-1
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.
Utilisation Category:
AC-1
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - ca
Depth:
140 mm
Maximum Operating Rate:
3600 cyc/h 60°C
Protective Treatment:
THIEC 60068-2-30
Coil Technology:
without built-in suppressor module
Ip Degree Of Protection:
IP20 front face IEC 60529
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Electrical Durability:
0.8 Mcycles 125 A AC-1 <= 440 V
Control Circuit Type:
AC 50/60 Hz
Sustainable Packaging:
Yes
Mounting Support:
rail || plate
Protective Cover:
without
Operating Altitude:
0...9842.52 ft (0...3000 m)
Range:
TeSys
Mechanical Durability:
4 Mcycles
Overvoltage Category:
III
Pvc Free:
Yes
Net Weight:
1.84 kg
Reach Free Of Svhc:
Yes
[Uc] Control Circuit Voltage:
120 V AC 50/60 Hz
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Toxic Heavy Metal Free:
Yes
[Ie] Rated Operational Current:
125 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Inrush Power In Va:
245-245 VA 60 Hz cos phi 0.75 (at 20°C) || 245-245 VA 50 Hz cos phi 0.75 (at 20°C)
Country of Origin:
Czechia
Climatic Withstand:
IACS E10 exposure to damp heat
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 990 A 40°C - 1 s for power circuit || 135 A 40°C - 10 min for power circuit || 320 A 40°C - 1 min for power circuit
Poles Description:
4P
Hold-In Power Consumption In Va:
26-26 VA 60 Hz cos phi 0.3 (at 20°C) || 26-26 VA 50 Hz cos phi 0.3 (at 20°C)
Power Dissipation Per Pole:
12.5 W AC-1
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile:
N/A
[Ith] Conventional Free Air Thermal Current:
125 A (at 60°C) for power circuit
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Control Circuit Voltage Limits:
0.85...1.1 Uc -40-55°C operational AC 60 Hz || 0.3...0.6 Uc -40-55°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55°C operational AC 50 Hz
$518.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 110A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.78 inches wide and 5.51 inches deep. It weighs 4.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose