Schneider Electric LC1DT32P7 IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 4 NO, 230VAC 50/60Hz coil, open style
Schneider Electric
$189.60
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 32A resistive load rating. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Operating Time:
- 4...19 ms opening || 12...22 ms closing
- Product Or Component Type:
- contactor
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Product Certifications:
- DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
- Warranty:
- 18 months
- Compatibility Code:
- LC1D
- [Uc] Control Circuit Voltage:
- 230 V AC 50/60 Hz
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Range:
- TeSys || TeSys Deca
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Pole Contact Composition:
- 4 NO
- Depth:
- 99 mm
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Power Dissipation Per Pole:
- 2.5 W AC-1
- Signaling Circuit Frequency:
- 25...400 Hz
- Range Of Product:
- TeSys Deca
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Protective Cover:
- with
- Control Circuit Type:
- AC 50/60 Hz
- Poles Description:
- 4P
- Country of Origin:
- United States
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Contactor Application:
- resistive load
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Mounting Support:
- rail || plate
- Weight:
- 0.425 kg
- Circularity Profile:
- ENVEOLI1501004
- Coil Technology:
- without built-in suppressor module
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
- Mercury Free:
- Yes
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Mechanical Durability:
- 15 Mcycles
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
- Average Impedance:
- 2.5 mOhm - Ith 32 A 50 Hz for power circuit
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- [Ie] Rated Operational Current:
- 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- [Icw] Rated Short-Time Withstand Current:
- 40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Height:
- 91 mm