TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Overvoltage Category:
- III
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Control Circuit Type:
- AC 50/60 Hz
- Mechanical Durability:
- 15 Mcycles
- Rohs Exemption Information:
- Yes
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Height:
- 91 mm
- Range Of Product:
- TeSys Deca
- Flame Retardance:
- V1 conforming to UL 94
- Weight:
- 0.425 kg
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Operating Time:
- 4...19 ms opening || 12...22 ms closing
- Electrical Durability:
- 1.4 Mcycles 40 A AC-1 <= 440 V
- Depth:
- 99 mm
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- Range:
- TeSys || TeSys Deca
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Sustainable Offer Status:
- Green Premium product
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
- Environmental Disclosure:
- ENVPEP110229EN
- Protective Treatment:
- THIEC 60068-2-30
- Product Certifications:
- DNV || GOST || BV || GL || CSA || UL || LROS (Lloyds register of shipping) || RINA || CCC
- Warranty:
- 18 months
- Mounting Support:
- rail || plate
- Coil Technology:
- without built-in suppressor module
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- [Ie] Rated Operational Current:
- 40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Average Impedance:
- 2 mOhm - Ith 40 A 50 Hz for power circuit
- Country of Origin:
- Indonesia
- [Icw] Rated Short-Time Withstand Current:
- 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Contactor Application:
- resistive load
- Circularity Profile:
- ENVEOLI110229EN
- Device Short Name:
- LC1D
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Poles Description:
- 4P
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
- Signaling Circuit Frequency:
- 25...400 Hz
- Power Dissipation Per Pole:
- 3.2 W AC-1
- Pollution Degree: