Schneider Electric

Schneider Electric LC1DT60AM7 IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 4 NO, 220VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT60AM7
MPN:
LC1DT60AM7
Condition:
New
Device Short Name:
LC1D
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Average Impedance:
1.6 mOhm - Ith 60 A 50 Hz for power circuit
Mercury Free:
Yes
Range:
TeSys || TeSys Deca
Height:
122 mm
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Net Weight:
1.09 kg
Circularity Profile:
ENVEOLI1503009EN
Pole Contact Composition:
4 NO
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Tightening Torque:
control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BT
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Minimum Switching Current:
5 mA for Signaling circuit
Product Or Component Type:
contactor
Operating Altitude:
0...9842.52 ft (0...3000 m)
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Pollution Degree:
3
Compatibility Code:
LC1D
Product Certifications:
LROS (Lloyds register of shipping) || UL || GOST || BV || CCC || CSA || RINA || DNV || GL
Reach Free Of Svhc:
Yes
[Uc] Control Circuit Voltage:
220 V AC 50/60 Hz
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Environmental Disclosure:
ENVPEP1503009EN
Contactor Application:
resistive load
Depth:
120 mm
Rohs Exemption Information:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Coil Technology:
without built-in suppressor module
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Electrical Durability:
1.4 Mcycles 60 A AC-1 <= 440 V
Weight:
1.09 kg
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Pvc Free:
Yes
Poles Description:
4P
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Operating Time:
4...19 ms opening || 12...26 ms closing
Fire Resistance:
850°C IEC 60695-2-1
Sustainable Offer Status:
Green Premium product
Minimum Switching Voltage:
17 V for Signaling circuit
[Icw] Rated Short-Time Withstand Current:
320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Flame Retardance:
V1 conforming to UL 94
Mechanical Durability:
6 Mcycles
Signaling Circuit Frequency:
25...400 Hz
$353.16

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose