Schneider Electric

Schneider Electric LC1DT80AQ7 IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 380VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT80AQ7
MPN:
LC1DT80AQ7
Condition:
New
Minimum Switching Voltage:
17 V for Signaling circuit
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Country of Origin:
France
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
[Icw] Rated Short-Time Withstand Current:
640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Compatibility Code:
LC1D
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Pole Contact Composition:
4 NO
Auxiliary Contact Composition:
1 NO + 1 NC
Toxic Heavy Metal Free:
Yes
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Range Of Product:
TeSys Deca
Device Short Name:
LC1D
Pollution Degree:
3
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Depth:
120 mm
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Heat Dissipation:
4-5 W at 50/60 Hz
Rohs Exemption Information:
Yes
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Maximum Operating Rate:
3600 cyc/h 60°C
Net Weight:
1.15 kg
Pvc Free:
Yes
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Mechanical Durability:
6 Mcycles
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Operating Altitude:
0...9842.52 ft (0...3000 m)
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || power circuit 5 N.m screw clamp terminals 1-25 mm² hex
Flame Retardance:
V1 conforming to UL 94
Coil Technology:
without built-in suppressor module
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Product Certifications:
GL || BV || UL || CCC || GOST || CSA || DNV || RINA || LROS (Lloyds register of shipping)
Product Or Component Type:
contactor
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Electrical Durability:
1.4 Mcycles 80 A AC-1 <= 440 V
Control Circuit Type:
AC 50/60 Hz
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Power Dissipation Per Pole:
10.2 W AC-1
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Average Impedance:
1.6 mOhm - Ith 80 A 50 Hz for power circuit
Signaling Circuit Frequency:
25...400 Hz
Eu Rohs Directive:
Compliant
$540.96

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 380 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.54 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose