Schneider Electric

Schneider Electric LC1G185KUEN Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 185A, 100-250VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G185KUEN
MPN:
LC1G185KUEN
Condition:
New
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Range Of Product:
TeSys Giga
Compatibility Code:
LC1G
Overvoltage Category:
III
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Average Impedance:
0.00017 Ohm
Operating Time:
40...70 ms closing || 15...50 ms opening
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Ambient Air Temperature For Operation:
-25-60°C
Net Weight:
3.6 kg
Auxiliary Contact Composition:
1 NO + 1 NC
Pole Contact Composition:
3 NO
Hold-In Power Consumption In Va:
12.4-12.4 VA
Coil Technology:
built-in bidirectional peak limiting
Range:
TeSys
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
Mechanical Durability:
8 Mcycles
Power Dissipation Per Pole:
20 W AC-1 - Ith 305 A || 6 W AC-3 - Ith 185 A
Eu Rohs Directive:
Compliant with Exemptions
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Country of Origin:
France
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Color:
dark grey
[Icw] Rated Short-Time Withstand Current:
1.5 kA - 10 s || 0.92 kA - 30 s || 0.74 kA - 1 min || 0.5 kA - 3 min || 0.4 kA - 10 min
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Tightening Torque:
18 N.m
Sustainable Offer Status:
Green Premium product
Depth:
193 mm
Rohs Exemption Information:
Yes
[Ie] Rated Operational Current:
305 A (at <40°C) at <= 1000 V AC-1 || 185 A (at <60°C) at <= 440 V AC-3
Maximum Horse Power Rating:
50 hp at 200/208 V 60 Hz || 60 hp at 230/240 V 60 Hz || 125 hp at 460/480 V 60 Hz || 150 hp at 575/600 V 60 Hz
Product Or Component Type:
contactor
Hold-In Power Consumption In W:
7.8-7.8 W
[Uimp] Rated Impulse Withstand Voltage:
8 kV
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
[Ui] Rated Insulation Voltage:
1000 V
Poles Description:
3P
[Ith] Conventional Free Air Thermal Current:
305 A (at 40°C)
Ambient Air Temperature For Storage:
-60-80°C
Irms Rated Making Capacity:
2310 A at 440 V
Connection Pitch:
35 mm
Motor Power Kw:
55 kW at 230 V AC 50/60 Hz (AC-3e) || 90 kW at 400 V AC 50/60 Hz (AC-3e) || 90 kW at 415 V AC 50/60 Hz (AC-3e) || 110 kW at 440 V AC 50/60 Hz (AC-3e) || 110 kW at 500 V AC 50/60 Hz (AC-3e) || 110 kW at 690 V AC 50/60 Hz (AC-3e) || 75 kW at 1000 V AC
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation:
X
Weight:
3.6 kg
Rated Breaking Capacity:
1610 A at 440 V
$850.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 185A 110kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose