Schneider Electric

Schneider Electric LC1G265BEEA Contactor, high power, TeSys Giga, advanced version, 3 pole/NO, AC-3 <=440V 265A, 24-48VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G265BEEA
MPN:
LC1G265BEEA
Condition:
New
China Rohs Regulation:
X
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Color:
dark grey
Range:
TeSys
Depth:
226 mm
Connection Pitch:
45 mm
Associated Fuse Rating:
315 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 400 A gG at <= 690 V
Weight:
8.2 kg
Country of Origin:
China
Average Impedance:
0.000144 Ohm
Motor Power Kw:
75 kW at 230 V AC 50/60 Hz (AC-3e) || 132 kW at 400 V AC 50/60 Hz (AC-3e) || 132 kW at 415 V AC 50/60 Hz (AC-3e) || 160 kW at 440 V AC 50/60 Hz (AC-3e) || 160 kW at 500 V AC 50/60 Hz (AC-3e) || 200 kW at 690 V AC 50/60 Hz (AC-3e) || 160 kW at 1000 V
[Icw] Rated Short-Time Withstand Current:
2.2 kA - 10 s || 1.23 kA - 30 s || 0.95 kA - 1 min || 0.62 kA - 3 min || 0.48 kA - 10 min
[Uc] Control Circuit Voltage:
24...48 V AC 50/60 Hz || 24...48 V DC
Hold-In Power Consumption In Va:
17.9-17.9 VA
Width:
140 mm
Net Weight:
8.2 kg
[Ui] Rated Insulation Voltage:
1000 V
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Coil Technology:
built-in bidirectional peak limiting
Overvoltage Category:
III
Operating Time:
40...70 ms closing || 15...50 ms opening
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
Ambient Air Temperature For Operation:
-25-60°C
Height:
290 mm
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Product Or Component Type:
contactor
Sustainable Offer Status:
Green Premium product
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Breaking Capacity:
2380 A at 440 V
Ambient Air Temperature For Storage:
-60-80°C
Mechanical Durability:
8 Mcycles
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Power Dissipation Per Pole:
20 W AC-1 - Ith 385 A || 11 W AC-3 - Ith 265 A
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Pole Contact Composition:
3 NO
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Inrush Power In W:
380 W
Device Short Name:
LC1G
Irms Rated Making Capacity:
3320 A at 440 V
Eu Rohs Directive:
Compliant with Exemptions
Halogen Content Performance:
Halogen free plastic parts product
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP2105013
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Pvc Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Maximum Horse Power Rating:
75 hp at 200/208 V 60 Hz || 100 hp at 230/240 V 60 Hz || 200 hp at 460/480 V 60 Hz || 200 hp at 575/600 V 60 Hz
Mounting Support:
plate
Compatibility Code:
LC1G
$1,570.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 265A 160kW@440V. It provides a 24-48V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose