Schneider Electric LC1G265KUEN Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 265A, 100-250VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G265KUEN
MPN:
LC1G265KUEN
Condition:
New
Average Impedance:
0.000144 Ohm
Mercury Free:
Yes
Overvoltage Category:
III
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Power Dissipation Per Pole:
20 W AC-1 - Ith 385 A || 11 W AC-3 - Ith 265 A
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Rated Breaking Capacity:
2380 A at 440 V
Auxiliary Contact Composition:
1 NO + 1 NC
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Eu Rohs Directive:
Compliant with Exemptions
Sustainable Offer Status:
Green Premium product
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Rohs Exemption Information:
Yes
Maximum Horse Power Rating:
75 hp at 200/208 V 60 Hz || 100 hp at 230/240 V 60 Hz || 200 hp at 460/480 V 60 Hz || 200 hp at 575/600 V 60 Hz
Coil Technology:
built-in bidirectional peak limiting
Product Or Component Type:
contactor
[Ie] Rated Operational Current:
385 A (at <40°C) at <= 1000 V AC-1 || 265 A (at <60°C) at <= 440 V AC-3
[Icw] Rated Short-Time Withstand Current:
2.2 kA - 10 s || 1.23 kA - 30 s || 0.95 kA - 1 min || 0.62 kA - 3 min || 0.48 kA - 10 min
Operating Time:
40...70 ms closing || 15...50 ms opening
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP2105013
Hold-In Power Consumption In Va:
15.0-15.0 VA
Circularity Profile:
ENVEOLI2105013
Contactor Application:
power switching || motor control
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
Pvc Free:
Yes
Hold-In Power Consumption In W:
9.1-9.1 W
Protective Treatment:
TH
Associated Fuse Rating:
315 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 400 A gG at <= 690 V
Tightening Torque:
35 N.m
Range:
TeSys
Net Weight:
7.5 kg
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-1 || UL 60335-2-40:Annex JJ
Inrush Power In W:
645 W
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Color:
dark grey
Pole Contact Composition:
3 NO
Halogen Content Performance:
Halogen free plastic parts product
Poles Description:
3P
Ambient Air Temperature For Storage:
-60-80°C
[Ith] Conventional Free Air Thermal Current:
385 A (at 40°C)
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Device Short Name:
LC1G
Mechanical Durability:
8 Mcycles
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
$1,370.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 265A 160kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose